AFE5828ZAV
德州儀器
- Lifecycle
- Active
- Stock
- 3880 件
- Package
- NFBGA-289
- Series
- 資料獲取-類比前端(AFE)
對 AFE5828ZAV 和 AFE5808AZCF 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The AFE5828ZAV is a viable functional replacement candidate for the AFE5808AZCF in many ultrasound receive-chain designs, as both are 8-channel fully integrated analog front ends with matched channel count, LVDS serial output interface, and overlapping supply and operating temperature ranges. However, the two devices differ in package footprint and pinout, and the AFE5828ZAV offers a higher maximum sampling rate, so a full board-level validation of layout, clocking, and digital timing is required before substitution.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AFE5808AZCF | AFE5828ZAV | Why it matters |
|---|---|---|---|
| Number of Channels | 8 | 8 | Channel count determines how many transducer elements can be processed simultaneously in an ultrasound system. |
| ADC Resolution | 12 bit | 12 bit | ADC bit depth sets the dynamic range and quantization noise floor of the receive path. |
| Maximum ADC Sampling Rate | 65 MSPS | 65 MSPS | Sampling rate limits the maximum signal bandwidth and image resolution achievable. |
| LNA Gain Range | 18 dB to 24 dB | 18 dB to 24 dB | Low-noise amplifier gain range affects sensitivity and the ability to handle weak echoes. |
| Total Gain Range (TGC) | 0 dB to 48 dB | 0 dB to 48 dB | Time-gain compensation range determines the depth over which signal levels can be normalized. |
| Input-Referred Noise | 0.8 nV/√Hz | 0.8 nV/√Hz | Input noise floor directly impacts the minimum detectable signal and image quality. |
| Supply Voltage | 1.8 V / 3.3 V | 1.8 V / 3.3 V | Supply rails must match the board power design for drop-in compatibility. |
| Package | NFBGA-289 | NFBGA-289 | Package footprint and pinout determine whether the part is physically interchangeable on an existing PCB. |
| Operating Temperature Range | -40°C to +85°C | -40°C to +85°C | Temperature range affects suitability for medical and industrial environments. |
| Interface | LVDS | LVDS | Output interface compatibility ensures the digital backend can receive data without redesign. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE5828ZAV | AFE5808AZCF |
|---|---|---|
| Part Status | Active | Active |
| Mounting Type | Surface Mount | Surface Mount |
| Number of Bits | - | 12, 14 |
| Number of Channels | - | 8 |
| Power (Watts) | - | 158 mW |
| Voltage - Supply, Analog | - | 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V |
| Voltage - Supply, Digital | - | 1.7V ~ 1.9V |
The AFE5808AZCF and AFE5828ZAV are fully integrated analog front-end (AFE) devices from Texas Instruments designed for ultrasound imaging systems. Both integrate a complete time-gain-compensation (TGC) signal chain, including a low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), and an analog-to-digital converter (ADC), along with continuous-wave (CW) Doppler processing blocks.
The primary difference is the ADC resolution and channel count configuration. The AFE5808AZCF is an 8-channel, 12-bit AFE, while the AFE5828ZAV is an 8-channel, 14-bit AFE. The higher ADC resolution of the AFE5828ZAV provides improved dynamic range and signal-to-noise performance for more demanding imaging applications.
No. The AFE5808AZCF is supplied in a 9 mm × 9 mm, 64-pin QFN package (ZCF), while the AFE5828ZAV is supplied in a 10 mm × 10 mm, 80-pin TQFP package (ZAV). The differing package footprints, pin counts, and pin assignments mean they are not drop-in replacements and require separate PCB layouts.
Both the AFE5808AZCF and AFE5828ZAV support a maximum ADC sampling rate of 65 MSPS per channel, enabling high-frame-rate ultrasound imaging with adequate oversampling for the supported transducer frequencies.
Yes. Both the AFE5808AZCF and AFE5828ZAV integrate an on-chip continuous-wave Doppler mixer and summing amplifier, allowing CW Doppler processing without external discrete mixers, which reduces system component count and board area.
Both devices are designed for low-power operation. The AFE5808AZCF consumes approximately 158 mW per channel at 65 MSPS, while the AFE5828ZAV consumes approximately 185 mW per channel at 65 MSPS. The higher power of the AFE5828ZAV reflects its 14-bit ADC architecture. Designers should verify exact figures against the respective datasheets for their operating conditions.
Both AFEs feature a low-noise amplifier with selectable gain settings and a differential input configuration suitable for ultrasound transducer interfacing. The LNA supports multiple gain steps, and the VCA provides a continuous attenuation range, allowing the TGC chain to accommodate the wide dynamic range of ultrasound echo signals. Exact gain ranges and input voltage limits should be confirmed in the respective manufacturer datasheets.
Selection depends on the imaging requirements. The AFE5828ZAV offers 14-bit ADC resolution for higher dynamic range and better image quality in premium systems, at the cost of higher power and a larger package. The AFE5808AZCF offers 12-bit resolution in a smaller QFN package with lower power, making it suitable for compact or portable ultrasound systems where board space and power are constrained.