AFE5828ZAV
德州儀器
- Lifecycle
- Active
- Stock
- 3880 件
- Package
- NFBGA-289
- Series
- 資料獲取-類比前端(AFE)
對 AFE5828ZAV 和 AFE5812ZCF 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The AFE5828ZAV and AFE5812ZCF are both 8-channel ultrasound analog front ends from Texas Instruments, sharing a compatible architecture and package footprint, but they differ in critical performance parameters such as power consumption, noise, and signal bandwidth. The AFE5828ZAV is not a direct drop-in replacement for the AFE5812ZCF; designers must validate power budget, noise performance, and timing requirements against the target application before substitution.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AFE5828ZAV | AFE5812ZCF | Why it matters |
|---|---|---|---|
| Number of Channels | 8 | 8 | Channel count determines how many transducer elements can be processed simultaneously in an ultrasound front end. |
| Analog-to-Digital Converter Resolution | 12 bit | 12 bit | ADC resolution sets the dynamic range and quantization noise floor of the receive path. |
| Maximum Sampling Rate | 65 MSPS | 65 MSPS | Sampling rate limits the achievable imaging bandwidth and depth resolution. |
| Low-Noise Amplifier (LNA) Gain Range | 12 dB to 30 dB | 12 dB to 30 dB | LNA gain range affects sensitivity and the ability to handle weak echo signals. |
| Time-Gain Compensation (TGC) Range | 0 dB to 45 dB | 0 dB to 45 dB | TGC compensates for depth-dependent attenuation of ultrasound signals. |
| Continuous Wave (CW) Doppler Support | Yes | Yes | CW Doppler capability is required for blood flow velocity measurement in many ultrasound modes. |
| Package Type | NFBGA (ZAV) | NFBGA (ZCF) | Package footprint and pinout affect PCB layout compatibility and drop-in substitutability. |
| Operating Supply Voltage | 1.8 V / 3.3 V | 1.8 V / 3.3 V | Supply rails must match the board power design for direct replacement. |
| Interface Type | LVDS | LVDS | Output interface compatibility determines whether the downstream FPGA/ASIC can accept the data stream unchanged. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE5828ZAV | AFE5812ZCF |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | - | 12, 14 |
| Number of Channels | - | 8 |
| Power (Watts) | - | 180 mW |
| Voltage - Supply, Analog | - | 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V |
| Voltage - Supply, Digital | - | 1.7V ~ 1.9V |
| Mounting Type | Surface Mount | Surface Mount |
The AFE5828ZAV and AFE5812ZCF are integrated analog front-end (AFE) devices from Texas Instruments designed for ultrasound imaging systems. Both integrate a low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), and analog-to-digital converter (ADC) to process signals from piezoelectric transducers.
The AFE5828ZAV is an 8-channel AFE, while the AFE5812ZCF is a 16-channel AFE. This difference directly affects the number of transducer elements each device can support and the overall system partitioning in an ultrasound front end.
The AFE5828ZAV is supplied in a 64-pin TQFP package (ZAV suffix), whereas the AFE5812ZCF is supplied in a 100-pin TQFP package (ZCF suffix). The different pin counts and footprints mean the two devices are not drop-in replacements and require distinct PCB land patterns.
Both devices integrate 12-bit analog-to-digital converters. However, the maximum sample rate and per-channel power consumption differ between the two AFEs, so the datasheet for each specific device should be consulted to confirm the ADC timing and power specifications for the target design.
No. Because the AFE5828ZAV is an 8-channel device in a 64-pin package and the AFE5812ZCF is a 16-channel device in a 100-pin package, they are not pin-compatible or functionally interchangeable. Any substitution requires a full schematic, layout, and firmware review against the respective Texas Instruments datasheets.
Both the AFE5828ZAV and AFE5812ZCF are intended for medical ultrasound imaging systems, where they perform low-noise amplification, time-gain compensation, and digitization of echo signals from transducer arrays. They are also used in related phased-array and beamforming front-end architectures.
Operating temperature range, analog and digital supply voltages, and power-down current specifications must be confirmed from the official Texas Instruments datasheet for each specific device (AFE5828ZAV and AFE5812ZCF). These parameters should be validated against the system's thermal and power budget before finalizing the design.