ADS1259IPWR
德州儀器
- Lifecycle
- Active
- Stock
- 6414 件
- Package
- TSSOP-20
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1259IPWR 和 ADS1230IPWG4 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1259IPWR and ADS1230IPWG4 are both 24-bit delta-sigma ADCs, but they differ fundamentally in resolution architecture, data rate, interface, and package, so the ADS1230IPWG4 cannot serve as a drop-in substitute for the ADS1259IPWR without redesign and validation.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1259IPWR | ADS1230IPWG4 | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 20 | Higher resolution provides finer measurement granularity; a 24-bit ADC can resolve smaller signal changes than a 20-bit device. |
| Maximum Sample Rate (SPS) | 14400 | 80 | Sample rate determines how fast the ADC can capture changing signals; the ADS1259 supports much higher throughput for faster measurements. |
| Number of Input Channels | 1 (single-ended) | 1 (differential) | Input configuration affects how the sensor connects; differential inputs reject common-mode noise while single-ended suits ground-referenced signals. |
| Interface Type | SPI | SPI | Both use SPI, but the ADS1259 offers a more flexible register-based SPI interface versus the simpler read-only interface of the ADS1230. |
| Supply Voltage (Analog) | 4.75 V to 5.25 V | 2.7 V to 5.3 V | Supply range determines compatibility with the system power rail; the ADS1230 supports lower-voltage operation down to 2.7 V. |
| Package Type | TSSOP-20 | TSSOP-16 | Package footprint and pin count affect PCB layout and drop-in compatibility; the two devices are not pin-compatible. |
| Operating Temperature Range | -40 °C to +105 °C | -40 °C to +85 °C | Wider temperature range allows operation in harsher environments; the ADS1259 supports higher ambient temperatures. |
| Input Type / PGA | No integrated PGA | Integrated PGA (gain 1 or 128) | An integrated PGA allows direct connection of low-level sensors like bridge transducers without external amplification. |
| Typical Power Consumption | ~13 mW | ~5 mW | Power consumption affects thermal budget and battery life; the ADS1230 is better suited to low-power applications. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1259IPWR | ADS1230IPWG4 |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Discontinued at Digi-Key |
| Number of Bits | 24 | 20 |
| Sampling Rate(Per Second) | 14k | 80 |
| Number of Inputs | 1 | 1 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | ADC | PGA-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 5V | 2.7V ~ 5.3V |
| Voltage - Supply, Digital | 2.7V ~ 5.25V | 2.7V ~ 5.3V |
| Features | PGA | PGA |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
The ADS1259IPWR is a 24-bit, 14.4 kSPS delta-sigma ADC with a programmable gain amplifier (PGA) and a serial peripheral interface (SPI), housed in a TSSOP-20 package. The ADS1230IPWG4 is a 20-bit, 80 SPS delta-sigma ADC with an integrated PGA and a two-wire serial interface, housed in a TSSOP-16 package. The ADS1259 offers higher resolution and faster data rates, while the ADS1230 is optimized for low-speed, low-power weigh-scale applications.
No. The ADS1259IPWR uses a TSSOP-20 package, while the ADS1230IPWG4 uses a TSSOP-16 package. They have different pin counts and pin functions, so they are not pin-to-pin compatible and cannot be directly substituted on the same PCB footprint.
The ADS1259IPWR supports data rates up to 14.4 kSPS, whereas the ADS1230IPWG4 supports a fixed data rate of 80 SPS. The ADS1259 is therefore suitable for higher-speed measurement applications, while the ADS1230 targets slow, high-resolution weigh-scale systems.
The ADS1259IPWR is a 24-bit ADC, and the ADS1230IPWG4 is a 20-bit ADC. The ADS1259 provides higher nominal resolution, which can translate to better effective number of bits (ENOB) in low-noise, low-speed configurations, but actual performance depends on gain, data rate, and circuit design as specified in the respective datasheets.
Yes. Both the ADS1259IPWR and ADS1230IPWG4 integrate a programmable gain amplifier. The ADS1259 PGA supports gains of 1 to 128, and the ADS1230 PGA supports gains of 1, 2, 64, and 128, as documented in their respective manufacturer datasheets. The available gain settings differ, so gain selection must be verified for each application.
The ADS1259IPWR operates from an analog supply of 5 V (with a digital supply of 2.7 V to 5.25 V) and typically consumes about 13 mW at 5 V. The ADS1230IPWG4 operates from a single 2.7 V to 5.3 V supply and typically consumes about 1.5 mW in normal operation, with a low-power standby mode. The ADS1230 is generally lower power, while the ADS1259 offers higher speed and resolution.
The ADS1230IPWG4 is generally more suitable for battery-powered weigh-scale designs because it is optimized for low-speed, low-power operation with a typical supply current in the low hundreds of microamperes and a fixed 80 SPS output rate. The ADS1259IPWR offers higher speed and resolution but typically consumes more power, making it better suited to higher-throughput or higher-resolution systems where power is less constrained.
No. The two devices differ in package (TSSOP-16 vs TSSOP-20), pinout, resolution (20-bit vs 24-bit), maximum data rate (80 SPS vs 14.4 kSPS), gain settings, and supply requirements. A drop-in replacement is not possible; any substitution requires a new PCB layout and firmware changes validated against the manufacturer datasheets.