ADS1259IPWR
德州儀器
- Lifecycle
- Active
- Stock
- 6414 件
- Package
- TSSOP-20
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1259IPWR 和 ADS1222IPWRG4 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1259IPWR and ADS1222IPWRG4 are not drop-in replacements for one another. They differ in resolution, architecture, input channel configuration, and package footprint, so substituting one for the other requires full schematic and layout redesign as well as firmware revalidation.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1259IPWR | ADS1222IPWRG4 | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma ADCs, so resolution alone does not differentiate them for substitutability. |
| Number of input channels | 1 (single-ended) | 2 (differential) | Channel count and input configuration determine how many signals can be measured and whether differential measurement is supported. |
| Maximum sample rate | 14 kSPS | 2 kSPS | Sample rate limits the bandwidth of signals that can be accurately digitized; the ADS1259 supports significantly faster conversion. |
| Interface type | SPI | SPI | Both use SPI, so the host microcontroller interface is compatible, easing drop-in replacement at the digital level. |
| Supply voltage (analog) | 5 V (4.75 V to 5.25 V) | 2.7 V to 5.5 V | The wider analog supply range of the ADS1222 allows operation at lower voltages, affecting system power design and compatibility. |
| Package | TSSOP-20 | TSSOP-16 | Different pin counts and footprints mean the PCB layout must be redesigned; they are not pin-compatible. |
| Operating temperature range | -40°C to +105°C | -40°C to +85°C | The wider temperature range of the ADS1259 suits harsher environments, while the ADS1222 is limited to standard industrial conditions. |
| Internal PGA / gain | No (external gain) | Yes (PGA, gain 1 to 128) | An integrated PGA allows direct amplification of small sensor signals, simplifying the analog front end for low-level inputs. |
| Input voltage range | 0 V to VREF (unipolar) | Differential, ±VREF/gain | Input range and polarity determine whether the ADC can directly digitize bipolar or only unipolar signals without external conditioning. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1259IPWR | ADS1222IPWRG4 |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Discontinued at Digi-Key |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 14k | 240 |
| Number of Inputs | 1 | 2 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | ADC | MUX-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 5V | 2.7V ~ 5.5V |
| Voltage - Supply, Digital | 2.7V ~ 5.25V | 2.7V ~ 5.5V |
| Features | PGA | Temperature Sensor |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
The ADS1259IPWR is a 24-bit, 14.4-kSPS delta-sigma ADC with an integrated low-noise PGA and a precision voltage reference, designed for high-resolution industrial measurement. The ADS1222IPWRG4 is a 24-bit, 2-kSPS delta-sigma ADC with a fixed-gain PGA and no integrated reference, intended for lower-speed, cost-sensitive sensor applications. The ADS1259 offers higher throughput and integrated reference, while the ADS1222 provides lower power and a smaller feature set.
No. The ADS1259IPWR is supplied in a TSSOP-20 package, while the ADS1222IPWRG4 is supplied in a TSSOP-16 package. The pin counts and pin functions differ, so they are not drop-in replacements and require different PCB land patterns.
The ADS1259IPWR supports data rates up to 14.4 kSPS in its high-speed mode. The ADS1222IPWRG4 supports data rates up to 2 kSPS. The ADS1259 is therefore better suited for applications requiring faster signal acquisition, while the ADS1222 targets low-speed precision sensing.
No. The ADS1259IPWR integrates a precision voltage reference, which reduces external component count. The ADS1222IPWRG4 does not include an integrated reference and requires an external reference voltage for ratiometric or absolute measurements.
The ADS1259IPWR includes a low-noise PGA with selectable gains of 1 to 128, supporting direct connection of low-level sensors. The ADS1222IPWRG4 includes a fixed-gain PGA of 1 to 128 as well, but its noise and throughput performance are optimized for lower-speed operation. Designers should compare noise density and effective resolution at the target gain and data rate.
The ADS1259IPWR operates from an analog supply of 5 V (with a digital supply of 2.7 V to 5.25 V) and typically consumes about 13 mW at 14.4 kSPS. The ADS1222IPWRG4 operates from a single 2.7 V to 5.5 V supply and typically consumes about 1.2 mW at 2 kSPS. The ADS1222 is significantly lower power, consistent with its lower throughput.
The ADS1259IPWR is generally more suitable for high-resolution industrial measurement because it combines 24-bit resolution, up to 14.4 kSPS throughput, a low-noise PGA, and an integrated precision reference. The ADS1222IPWRG4 is better suited to lower-speed, lower-power sensor interfaces where an external reference is acceptable.
No. Direct replacement is not possible without redesign because the two devices differ in package (TSSOP-16 vs TSSOP-20), pinout, maximum sample rate, reference architecture, and supply/power characteristics. Any substitution must be validated against the manufacturer datasheets and the target system requirements.