ADS1222IPWR
德州儀器
- Lifecycle
- Active
- Stock
- 3095 件
- Package
- TSSOP-14
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1222IPWR 和 ADS1208IPWR 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1222IPWR and ADS1208IPWR are not functionally interchangeable. The ADS1222IPWR is a 24-bit delta-sigma ADC with an SPI interface and integrated PGA, while the ADS1208IPWR is a 16-bit second-order delta-sigma modulator with a single-bit output stream. They differ in resolution, output interface, input architecture, and package pinout, so the ADS1208IPWR cannot directly replace the ADS1222IPWR in an existing design without significant rework.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1222IPWR | ADS1208IPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 16 | Higher resolution enables finer measurement of small signal changes; a 24-bit ADC provides significantly more precision than a 16-bit device. |
| Architecture | Delta-Sigma (2-channel) | Delta-Sigma modulator | The ADS1222 integrates a full ADC with digital filter and two input channels, while the ADS1208 is a modulator-only device requiring external digital filtering, affecting system design complexity. |
| Input Channels | 2 differential | 1 differential | Number of input channels determines how many signals can be measured without external multiplexing; the ADS1222 supports twice the input capacity. |
| Output Interface | SPI (serial) | Serial bit-stream modulator output | The interface type dictates how the device connects to a host controller; SPI provides a standard register-based readout, whereas the modulator output requires a dedicated digital filter (e.g., sinc filter) in the host. |
| Data Rate / Output Frequency | Up to 2 kSPS (programmable) | Up to 10 MHz modulator clock | Data rate affects measurement speed and noise trade-off; the ADS1208's high modulator clock supports fast oversampling for high-speed current sensing, while the ADS1222 targets slower precision measurements. |
| Typical Application | Precision sensor and temperature measurement | Motor control and current sensing | The intended application indicates functional substitutability; the ADS1222 suits low-speed precision sensing, while the ADS1208 is optimized for isolated current-shunt measurement in motor drives. |
| Supply Voltage | 2.7 V to 5.5 V | 4.5 V to 5.5 V | Supply range determines compatibility with the system power rail; the ADS1222 operates down to 2.7 V, allowing use in lower-voltage systems where the ADS1208 cannot operate. |
| Package | TSSOP-16 | TSSOP-16 | Package footprint affects PCB layout and drop-in compatibility; identical TSSOP-16 packages allow the same board footprint, though pinout must still be verified. |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | Temperature range confirms suitability for industrial environments; both devices share the same industrial-grade range, so thermal constraints are equivalent. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1222IPWR | ADS1208IPWR |
|---|---|---|
| Supplier | - | Texas Instruments,Rochester Electronics, LLC |
| Part Status | Active | Obsolete |
| Type | - | Modulator |
| Number of Channels | - | 1 |
| Resolution(Bits) | - | 16 b |
| Sampling Rate(Per Second) | 240 | 40k |
| Data Interface | SPI | Serial |
| Voltage Supply Source | - | Analog and Digital |
| Voltage - Supply | - | 2.7V ~ 5.5V, 4.5V ~ 5.5V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | - | Surface Mount |
| Number of Bits | 24 | - |
| Number of Inputs | 2 | - |
| Input Type | Differential, Single Ended | - |
| Configuration | MUX-ADC | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External | - |
| Voltage - Supply, Analog | 2.7V ~ 5.5V | - |
| Voltage - Supply, Digital | 2.7V ~ 5.5V | - |
| Features | Temperature Sensor | - |
The ADS1222IPWR is a 24-bit delta-sigma analog-to-digital converter with a two-channel differential input multiplexer, a programmable gain amplifier, and an internal oscillator, intended for precision sensor measurement. The ADS1208IPWR is a 16-bit delta-sigma modulator with a single differential input and a digital output stream, intended for isolated current sensing and motor control applications. The ADS1222 integrates a full ADC signal chain, while the ADS1208 provides a modulated bitstream requiring external digital filtering.
No. The ADS1222IPWR provides 24-bit resolution, whereas the ADS1208IPWR is a 16-bit delta-sigma modulator. The resolution figures are not interchangeable, and the ADS1208 output must be processed by a digital filter to reconstruct the conversion result.
No. Both devices are offered in a TSSOP-16 package (PW suffix), but their pin functions differ. The ADS1222IPWR exposes analog inputs, reference, and serial interface pins for a complete ADC, while the ADS1208IPWR exposes a modulator clock input and a single-bit data output. The PCB land pattern may be similar, but the pin assignments are not interchangeable.
Both devices support a single 5 V analog supply, but their digital supply requirements differ. The ADS1222IPWR operates from a 2.7 V to 5.5 V analog supply and a 2.7 V to 5.5 V digital supply. The ADS1208IPWR operates from a 4.5 V to 5.5 V analog supply and a 2.7 V to 5.5 V digital supply. Designs must verify both rails against the respective datasheet limits.
The ADS1208IPWR is intended for isolated current sensing because its delta-sigma modulator output can be coupled through a digital isolator, and it is specified for operation with a shunt resistor in motor control and power conversion applications. The ADS1222IPWR is a complete ADC intended for direct precision sensor measurement and does not provide the same modulator-only signal path.
No. The ADS1222IPWR includes on-chip digital filtering and provides a complete serial conversion result. The ADS1208IPWR outputs a 1-bit delta-sigma modulated stream and requires an external digital filter, typically implemented in an FPGA, DSP, or microcontroller, to produce a usable conversion value.
The ADS1222IPWR provides a two-channel differential input multiplexer with a programmable gain amplifier. The ADS1208IPWR provides a single differential input intended for shunt-resistor current measurement. The channel count and input architecture are therefore not equivalent.
No. A direct replacement is not possible because the devices differ in resolution, output format, input configuration, and pin functions. The ADS1222IPWR provides a complete filtered ADC output, while the ADS1208IPWR provides a modulator bitstream requiring external filtering. Any substitution requires a full schematic, firmware, and signal-chain redesign validated against the manufacturer datasheets.