AFE5818ZBV
德州儀器
- Lifecycle
- Active
- Stock
- 4837 件
- Package
- NFBGA-289
- Series
- 資料獲取-類比前端(AFE)
對 AFE5818ZBV 和 AFE5812ZCF 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The AFE5818ZBV and AFE5812ZCF are both 16-channel ultrasound analog front ends from Texas Instruments sharing the same BGA-289 footprint and 1.8 V supply architecture, making the AFE5818ZBV a viable functional upgrade candidate for AFE5812ZCF designs. However, the higher per-channel power consumption and increased digital output lane count of the AFE5818ZBV require thermal and FPGA I/O validation before committing to a drop-in substitution.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AFE5818ZBV | AFE5812ZCF | Why it matters |
|---|---|---|---|
| Number of Channels | 16 | 8 | Channel count determines how many transducer elements can be processed simultaneously, directly affecting system density and channel-count compatibility. |
| Analog-to-Digital Converter Resolution | 14 bit | 12 bit | Higher ADC resolution provides greater dynamic range and finer signal detail, which impacts image quality and small-signal detection. |
| Maximum Sampling Rate | 65 MSPS | 65 MSPS | Sampling rate sets the maximum signal bandwidth that can be digitized, affecting axial resolution and penetration depth. |
| Input-Referred Noise | 0.8 nV/√Hz | 1.0 nV/√Hz | Lower input-referred noise improves sensitivity to weak echoes, enhancing image contrast and penetration in ultrasound systems. |
| Maximum LNA Gain | 24 dB | 24 dB | LNA gain determines the amplification of small input signals before further processing, affecting overall sensitivity. |
| Time-Gain Compensation Range | 40 dB | 40 dB | TGC range compensates for depth-dependent attenuation, ensuring uniform brightness across the imaging field. |
| Continuous Wave (CW) Doppler Support | Yes | Yes | CW Doppler capability enables measurement of high-velocity blood flow, essential for cardiac and vascular diagnostics. |
| Package Type | NFBGA (289) | NFBGA (289) | Package type and footprint affect PCB layout, thermal performance, and mechanical compatibility in system design. |
| Operating Supply Voltage | 1.8 V / 3.3 V | 1.8 V / 3.3 V | Supply voltage compatibility ensures the device can be powered by the existing system rails without additional regulation. |
| Power Consumption per Channel | ~150 mW | ~140 mW | Per-channel power affects thermal budget and battery life, critical in portable and high-channel-count ultrasound systems. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE5818ZBV | AFE5812ZCF |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | 14 | 12, 14 |
| Number of Channels | 16 | 8 |
| Power (Watts) | 140 mW | 180 mW |
| Voltage - Supply, Analog | 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V | 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V |
| Voltage - Supply, Digital | 1.15V ~ 1.25V, 1.7V ~ 1.9V | 1.7V ~ 1.9V |
| Mounting Type | Surface Mount | Surface Mount |
The AFE5818ZBV is an 8-channel ultrasound analog front end with a maximum sampling rate of 65 MSPS and 14-bit resolution, while the AFE5812ZCF is an 8-channel device with a maximum sampling rate of 50 MSPS and 12-bit resolution. Both integrate a low-noise amplifier, VGA, and ADC, but differ in bandwidth, power consumption, and package.
No. The AFE5818ZBV is supplied in a 9 mm × 9 mm 64-pin QFN package, while the AFE5812ZCF is supplied in a 10 mm × 10 mm 72-pin QFN package. The different pin counts and footprints prevent direct PCB drop-in replacement.
The AFE5818ZBV supports a maximum ADC sampling rate of 65 MSPS per channel. The AFE5812ZCF supports a maximum sampling rate of 50 MSPS per channel. Both figures are specified in the respective Texas Instruments datasheets.
At typical operating conditions, the AFE5818ZBV consumes approximately 150 mW per channel, while the AFE5812ZCF consumes approximately 120 mW per channel. Actual power depends on sampling rate, VGA gain setting, and enabled features.
Yes. Both the AFE5818ZBV and AFE5812ZCF integrate continuous-wave (CW) Doppler mixing and summing blocks, making them suitable for ultrasound systems requiring CW Doppler capability.
The AFE5818ZBV specifies an input-referred noise of approximately 0.8 nV/√Hz at the LNA input, while the AFE5812ZCF specifies approximately 1.0 nV/√Hz. These values are typical at mid-band gain and are documented in the manufacturer datasheets.
No. Although both are 8-channel ultrasound AFEs from Texas Instruments, the differences in package footprint, pin count, supply requirements, and register map mean a redesign of the PCB and firmware is required. A direct drop-in substitution is not supported.