ADS124S08IPBS
德州儀器
- Lifecycle
- Active
- Stock
- 3448 件
- Package
- TQFP-32
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS124S08IPBS 和 ADS1292RIPBSR 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1292RIPBSR and ADS124S08IPBS are not drop-in replacements for one another. The ADS1292RIPBSR is a dedicated two-channel biopotential front-end with integrated respiration impedance measurement, while the ADS124S08IPBS is a precision 12-channel delta-sigma ADC for general sensor measurement. Their channel architecture, integrated functionality, and target application domains differ fundamentally, so substituting one for the other requires complete redesign of the signal chain rather than a direct swap.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1292RIPBSR | ADS124S08IPBS | Why it matters |
|---|---|---|---|
| Number of input channels | 2 differential (2 ADC channels) | 12 single-ended / 6 differential (1 ADC, multiplexed) | Determines how many signals can be acquired; the ADS124S08 supports far more channels via an input multiplexer, while the ADS1292R is fixed at two channels. |
| Resolution | 24-bit | 24-bit | Both provide 24-bit delta-sigma conversion, so nominal resolution is equivalent for precision measurement applications. |
| Primary application focus | ECG / biopotential (integrated respiration impedance) | General-purpose precision sensor measurement (RTD, thermocouple, bridge) | The ADS1292R includes ECG-specific front-end features and respiration impedance measurement, whereas the ADS124S08 is a general-purpose precision ADC, affecting functional substitutability. |
| Integrated PGA gain range | 1 to 12 (programmable) | 1 to 128 (programmable) | A wider PGA range on the ADS124S08 allows amplification of very small sensor signals, improving dynamic range for low-level inputs. |
| Data output interface | SPI (compatible) | SPI (compatible) | Both use an SPI-compatible serial interface, simplifying digital host connection and firmware reuse. |
| Supply voltage (analog) | 2.7 V to 5.25 V (unipolar) / ±2.5 V (bipolar) | 2.7 V to 5.25 V (analog) / 2.7 V to 3.6 V (digital) | Supply requirements affect board-level power design and compatibility with existing rails; both support similar analog rails but differ in digital supply constraints. |
| Package | TQFP-32 (5 mm x 5 mm) | TQFP-32 (5 mm x 5 mm) | Identical package and footprint enable potential drop-in board layout reuse, though pin functions differ. |
| Integrated features | Integrated ECG front-end, respiration impedance measurement, lead-off detection, internal oscillator | Input multiplexer, PGA, reference buffer, IDACs, internal oscillator, sensor biasing | On-chip feature sets differ substantially; the ADS1292R targets biopotential acquisition while the ADS124S08 targets general sensor excitation and biasing, limiting direct substitution. |
| Operating temperature range | -40 °C to +85 °C | -40 °C to +125 °C | A wider temperature range on the ADS124S08 suits harsher industrial environments, while the ADS1292R is limited to standard commercial/industrial ranges. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS124S08IPBS | ADS1292RIPBSR |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 4k | - |
| Number of Inputs | 12 | - |
| Input Type | Single Ended | - |
| Data Interface | SPI | - |
| Configuration | MUX-PGA-ADC | - |
| Ratio - S / H: ADC | 0:1 | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External, Internal | - |
| Voltage - Supply, Analog | 2.7V ~ 5.25V | 2.7V ~ 5.25V |
| Voltage - Supply, Digital | 2.7V ~ 3.6V | 1.7V ~ 3.6V |
| Features | PGA | - |
| Operating Temperature | -50°C ~ 125°C | - |
| Number of Channels | - | 2 |
| Power (Watts) | - | 740 µW |
| Mounting Type | - | Surface Mount |
The ADS1292RIPBSR is a 2-channel, 24-bit delta-sigma analog front-end (AFE) designed specifically for biopotential measurements such as ECG and respiration, integrating a respiration impedance measurement block. The ADS124S08IPBS is an 8-channel (4 differential/8 single-ended), 24-bit delta-sigma ADC designed for precision sensor and industrial measurement applications, without an integrated respiration impedance block.
Both devices are offered in a TQFP-32 (PBS) package, but they are not pin-to-pin compatible. The ADS1292RIPBSR and ADS124S08IPBS have different pin functions and internal architectures, so a direct drop-in replacement is not possible without PCB redesign and firmware changes.
The ADS1292RIPBSR provides 2 differential input channels optimized for biopotential signals. The ADS124S08IPBS provides 8 single-ended or 4 differential inputs, offering greater channel count for multi-sensor precision measurement systems.
The ADS1292RIPBSR is specifically designed for ECG and respiration applications, featuring an integrated respiration impedance measurement function and a low-noise biopotential AFE. The ADS124S08IPBS is a general-purpose precision ADC and does not include a dedicated respiration impedance measurement block, making the ADS1292RIPBSR the more appropriate choice for that application.
The ADS1292RIPBSR integrates a PGA with selectable gains (1, 2, 3, 4, 6, 8, 12) and supports data rates up to 8 kSPS per channel. The ADS124S08IPBS integrates a PGA with gains from 1 to 128 and supports programmable data rates up to 4 kSPS. The ADS124S08IPBS offers wider gain range, while the ADS1292RIPBSR offers higher maximum output data rate.
No. Although both are 24-bit delta-sigma converters in TQFP-32 packages, they differ in channel count, pin functions, integrated features (the ADS1292RIPBSR includes a respiration impedance block), and register maps. A direct replacement would require hardware and firmware redesign and full revalidation against the target application requirements.
The ADS1292RIPBSR operates from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 1.7 V to 3.6 V. The ADS124S08IPBS operates from an analog supply of 2.7 V to 5.25 V and a digital supply of 2.7 V to 3.6 V. Designers should confirm exact supply ranges against the respective manufacturer datasheets for the target operating conditions.
Both devices provide 24-bit delta-sigma conversion. The ADS124S08IPBS is optimized for precision industrial sensor measurement with a wide PGA gain range up to 128 and low-noise performance, while the ADS1292RIPBSR is optimized for biopotential signal acquisition. The appropriate choice depends on the sensor type, signal amplitude, and required noise performance rather than resolution alone.