ADR02BRZ vs ADR02AR-REEL7

對 ADR02BRZ 和 ADR02AR-REEL7 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADR02BRZ and ADR02AR-REEL7 are functionally compatible voltage reference ICs sharing the same 5.0 V output, series topology, and SOIC-8 package, making the ADR02BRZ a viable replacement candidate for the ADR02AR-REEL7 in most designs. The primary distinction is the tighter initial accuracy and lower temperature coefficient grade of the ADR02BRZ, which meets or exceeds the ADR02AR-REEL7 specifications; however, designers should confirm that the improved grade does not affect any calibration assumptions and verify availability in the required reel packaging format.

Output Voltage High match
Package Type High match
Initial Accuracy Grade Validation required
Temperature Coefficient Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADR02BRZ ADR02AR-REEL7 Why it matters
Initial Accuracy ±0.06% (B grade) ±0.1% (A grade) Tighter initial tolerance directly affects system accuracy at room temperature; the B grade offers better guaranteed precision than the A grade.
Temperature Coefficient 3 ppm/°C max (B grade) 10 ppm/°C max (A grade) Lower tempco reduces drift over temperature, which is critical for precision measurement and industrial applications.
Output Voltage 5.0 V 5.0 V Both provide the same nominal reference voltage, so the output level is functionally interchangeable.
Package 8-Lead SOIC 8-Lead SOIC Identical package ensures drop-in PCB compatibility without layout changes.
Supply Voltage Range 7 V to 36 V 7 V to 36 V Same input range means both parts work in the same supply environment.
Operating Temperature Range -40°C to +125°C -40°C to +125°C Equivalent temperature ratings allow use in the same environmental conditions.
Output Current Capability 10 mA (source/sink) 10 mA (source/sink) Same drive capability supports the same load conditions in the application.
Long-Term Drift 25 ppm/1000 hr (B grade) 50 ppm/1000 hr (A grade) Lower long-term drift improves stability over the product lifetime, important for calibration-sensitive designs.
Grade / Precision Class B grade (higher precision) A grade (standard precision) The grade determines guaranteed accuracy and drift specs; substituting A for B may degrade system performance.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADR02BRZ ADR02AR-REEL7
Part Status Active Obsolete
Reference Type Series Series
Output Type Fixed Fixed
Voltage - Output (Min/Fixed) 5V 5V
Current - Output 10 mA 10 mA
Tolerance ±0.06% ±0.1%
Temperature Coefficient 3ppm/°C 10ppm/°C
Noise - 01 Hzto10 Hz 10µVp-p 10µVp-p
Voltage - Input 7V ~ 36V 7V ~ 36V
Supply Current 1mA 1mA
Operating Temperature -40°C ~ 125°C (TA) -40°C ~ 125°C (TA)
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the ADR02BRZ and ADR02AR-REEL7?

Both are ADR02 5.0 V precision voltage references from Analog Devices in an 8-lead SOIC package, but they differ in grade and packaging. The ADR02BRZ is a B-grade device with a tighter initial accuracy of ±0.06% maximum and a temperature coefficient of 3 ppm/°C maximum, supplied in tube form. The ADR02AR-REEL7 is an A-grade device with ±0.1% maximum initial accuracy and 5 ppm/°C maximum temperature coefficient, supplied on a 7-inch tape-and-reel. The B-grade part therefore offers tighter guaranteed specifications, while the A-grade reel version is oriented toward automated high-volume assembly.

Are the ADR02BRZ and ADR02AR-REEL7 pin-compatible?

Yes. Both devices are ADR02 references in the standard 8-lead SOIC (R-8) package with the same pinout, so they are footprint-compatible on the same PCB land pattern. The difference lies in guaranteed electrical grade and delivery format, not in pin assignment or package outline.

What is the output voltage and initial accuracy of each part?

Both provide a 5.000 V output. The ADR02BRZ guarantees ±0.06% maximum initial accuracy (approximately ±3 mV), while the ADR02AR-REEL7 guarantees ±0.1% maximum initial accuracy (approximately ±5 mV). These figures are the datasheet maximum limits for the respective grades.

How do the temperature coefficients of the two grades compare?

The ADR02BRZ (B-grade) is specified at 3 ppm/°C maximum temperature coefficient, and the ADR02AR-REEL7 (A-grade) is specified at 5 ppm/°C maximum. The B-grade therefore provides tighter drift performance over the operating temperature range, which matters in precision data-acquisition and instrumentation designs.

What supply voltage and current do these references require?

The ADR02 family operates from a supply of 7 V to 40 V and typically draws about 0.65 mA of quiescent current with no load. Both the ADR02BRZ and ADR02AR-REEL7 share these operating conditions, as they are the same base reference design in different grades.

What is the difference in packaging and delivery format?

The ADR02BRZ is supplied in standard tube packaging, which suits low-to-medium volume production and prototyping. The ADR02AR-REEL7 is supplied on a 7-inch tape-and-reel with 750 units per reel, which is compatible with automated pick-and-place assembly lines. The reel suffix does not change the device's electrical grade, which is set by the A-grade designation.

Can the ADR02AR-REEL7 be used as a drop-in replacement for the ADR02BRZ?

Electrically and mechanically it can be placed in the same socket, but it is not a specification-equivalent replacement. The A-grade part has looser guaranteed initial accuracy (±0.1% vs ±0.06%) and temperature coefficient (5 ppm/°C vs 3 ppm/°C). A design that relies on the B-grade limits must re-validate its error budget before substituting the A-grade device.

What are the operating temperature ranges for these references?

Both the ADR02BRZ and ADR02AR-REEL7 are specified over the industrial temperature range of −40 °C to +125 °C. The grade-dependent temperature coefficient limits apply across this range.