ADR02BRZ vs ADR02ARZ

對 ADR02BRZ 和 ADR02ARZ 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADR02ARZ and ADR02BRZ are functionally interchangeable voltage reference ICs sharing identical package, pinout, output voltage, and operating temperature range; the ADR02BRZ offers a tighter initial accuracy and lower temperature coefficient, making it a valid drop-in upgrade for precision-critical designs while the ADR02ARZ remains suitable for less demanding applications.

Output Voltage High match
Package Type High match
Operating Temperature Range High match
Initial Accuracy and Temperature Coefficient Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADR02ARZ ADR02BRZ Why it matters
Initial Accuracy (Vout) ±0.1% (5 mV max) ±0.06% (3 mV max) Tighter initial tolerance reduces system calibration effort and improves output accuracy at power-up.
Temperature Coefficient 10 ppm/°C max 3 ppm/°C max Lower tempco means less drift over temperature, critical for precision measurement and industrial applications.
Output Voltage 5.0 V 5.0 V Both provide the same nominal output, so the reference voltage is functionally interchangeable.
Package / Mounting 8-SOIC (surface mount) 8-SOIC (surface mount) Identical footprint allows drop-in replacement without PCB redesign.
Supply Voltage Range 7 V to 36 V 7 V to 36 V Same input range ensures compatibility with the same power supply rails.
Output Current Capability 10 mA (source/sink) 10 mA (source/sink) Matching drive capability supports the same load conditions in the target circuit.
Operating Temperature Range -40 °C to +125 °C -40 °C to +125 °C Same temperature range ensures both parts suit the same environmental conditions.
Supply Current 1 mA max 1 mA max Equivalent quiescent current keeps power budget unchanged when substituting parts.
Long-Term Stability 25 ppm/1000 h (typical) 25 ppm/1000 h (typical) Long-term drift affects recalibration intervals; both grades share the same stability specification.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADR02BRZ ADR02ARZ
Part Status Active Active
Reference Type Series Series
Output Type Fixed Fixed
Voltage - Output (Min/Fixed) 5V 5V
Current - Output 10 mA 10 mA
Tolerance ±0.06% ±0.1%
Temperature Coefficient 3ppm/°C 10ppm/°C
Noise - 01 Hzto10 Hz 10µVp-p 10µVp-p
Voltage - Input 7V ~ 36V 7V ~ 36V
Supply Current 1mA 1mA
Operating Temperature -40°C ~ 125°C (TA) -40°C ~ 125°C (TA)
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What is the main difference between the ADR02ARZ and ADR02BRZ?

The primary difference is the initial accuracy grade. The ADR02ARZ offers an initial output voltage accuracy of ±0.1%, while the ADR02BRZ offers a tighter initial accuracy of ±0.06%. Both are 5.0 V precision voltage references in an 8-lead SOIC package.

Are the ADR02ARZ and ADR02BRZ pin-compatible and package-compatible?

Yes. Both devices are offered in the same 8-lead SOIC (R-8) package with identical pin functions, so they are pin-to-pin and package-compatible. The difference is limited to the specified accuracy grade.

What is the output voltage and temperature coefficient of these references?

Both the ADR02ARZ and ADR02BRZ provide a 5.0 V output. The ADR02ARZ is specified with a temperature coefficient of 3 ppm/°C (B grade is 1 ppm/°C), while the ADR02BRZ is specified at 1 ppm/°C over the operating temperature range.

Can the ADR02ARZ be used as a drop-in replacement for the ADR02BRZ?

Functionally and mechanically yes, but the ADR02ARZ has a wider initial accuracy tolerance (±0.1% vs ±0.06%) and a higher temperature coefficient (3 ppm/°C vs 1 ppm/°C). It should only be substituted if the looser specifications still meet the design requirements.

What are the operating temperature ranges for the ADR02ARZ and ADR02BRZ?

Both devices are specified for the extended industrial temperature range of −40°C to +125°C, making them suitable for demanding industrial and instrumentation applications.

What is the long-term stability specification for these voltage references?

Both the ADR02ARZ and ADR02BRZ are specified with a long-term stability of 50 ppm per 1,000 hours at 25°C, which supports stable performance in precision measurement systems over time.

What supply voltage and current do the ADR02ARZ and ADR02BRZ require?

Both devices operate from a supply voltage of 7 V to 40 V and typically draw 0.65 mA of quiescent current, allowing them to be used in a wide range of precision analog circuits.