規格
| 屬性 | 價值 |
| Package | Tape & Reel (TR),Cut Tape (CT) |
| ProductStatus | Active |
| NumberofBits | 16, 24 |
| NumberofChannels | 8 |
| Power(Watts) | 17.6 mW |
| Voltage-SupplyAnalog | 2.7V ~ 5.25V |
| Voltage-SupplyDigital | 1.8V ~ 3.6V |
| MountingType | Surface Mount |
| Package/Case | 64-TQFP |
概述
Description
The ADS131E08IPAGR is a 24-bit, 8-channel, simultaneous-sampling delta-sigma ADC from Texas Instruments, designed for high-precision data acquisition. It features low noise (1.5 µV RMS), a programmable gain amplifier (PGA), and supports SPI communication.
Key features:
- 8 differential inputs with ±2.5V input range.
- Up to 128 kSPS sampling rate per channel.
- Low power consumption (3.3 mW/channel at 1 kSPS).
- Integrated reference and oscillator for reduced external components.
- CRC error detection for robust data integrity.
Applications include medical instrumentation, industrial sensors, and energy monitoring. The TQFP-64 package ensures compact PCB integration.
Its high resolution, low noise, and multi-channel capability make it ideal for precision measurement systems.
Key features:
- 8 differential inputs with ±2.5V input range.
- Up to 128 kSPS sampling rate per channel.
- Low power consumption (3.3 mW/channel at 1 kSPS).
- Integrated reference and oscillator for reduced external components.
- CRC error detection for robust data integrity.
Applications include medical instrumentation, industrial sensors, and energy monitoring. The TQFP-64 package ensures compact PCB integration.
Its high resolution, low noise, and multi-channel capability make it ideal for precision measurement systems.
Equivalent
Equivalent products to the ADS131E08IPAGR (8-channel, 24-bit delta-sigma ADC) include:
- ADS131E08SIPAGR (same specs, different package).
- ADS131M08 (higher performance, similar features).
- ADS1298 (medical-grade, 8-channel).
- LTC2512-24 (24-bit, lower channel count).
- MAX11198 (24-bit, 8-channel, lower power).
Check datasheets for exact compatibility.
- ADS131E08SIPAGR (same specs, different package).
- ADS131M08 (higher performance, similar features).
- ADS1298 (medical-grade, 8-channel).
- LTC2512-24 (24-bit, lower channel count).
- MAX11198 (24-bit, 8-channel, lower power).
Check datasheets for exact compatibility.
Features
The ADS131E08IPAGR is an 8-channel, 24-bit, delta-sigma ADC with these key features:
- High Resolution: 24-bit ADC with up to 32 kSPS per channel.
- Low Noise: 2.4 µV RMS noise at 1 kSPS.
- Low Power: 1 mW per channel at 1 kSPS.
- Flexible Inputs: Supports differential or single-ended inputs with PGA (gain: 1–128).
- Integrated Features: On-chip reference (2.4 V), oscillator, and fault detection.
- SPI Interface: High-speed communication with daisy-chain support.
- Wide Supply Range: 2.7 V to 3.6 V (analog), 1.65 V to 3.6 V (digital).
- Applications: Medical, industrial, and energy monitoring systems.
Packaged in a 64-pin TQFP, it offers high precision and low power for multi-channel data acquisition.
- High Resolution: 24-bit ADC with up to 32 kSPS per channel.
- Low Noise: 2.4 µV RMS noise at 1 kSPS.
- Low Power: 1 mW per channel at 1 kSPS.
- Flexible Inputs: Supports differential or single-ended inputs with PGA (gain: 1–128).
- Integrated Features: On-chip reference (2.4 V), oscillator, and fault detection.
- SPI Interface: High-speed communication with daisy-chain support.
- Wide Supply Range: 2.7 V to 3.6 V (analog), 1.65 V to 3.6 V (digital).
- Applications: Medical, industrial, and energy monitoring systems.
Packaged in a 64-pin TQFP, it offers high precision and low power for multi-channel data acquisition.
Application
The ADS131E08IPAGR is a high-precision, 8-channel, 24-bit delta-sigma ADC designed for applications requiring low-noise, high-resolution data acquisition. Key application areas include:
- Medical Devices: ECG, EEG, patient monitoring.
- Industrial Automation: PLCs, sensor interfaces, motor control.
- Energy Monitoring: Smart meters, power quality analysis.
- Test & Measurement: Data loggers, precision instrumentation.
- Consumer Electronics: Audio processing, wearable health tech.
Its low power consumption, high accuracy, and multi-channel capability make it ideal for systems demanding reliable analog signal processing.
- Medical Devices: ECG, EEG, patient monitoring.
- Industrial Automation: PLCs, sensor interfaces, motor control.
- Energy Monitoring: Smart meters, power quality analysis.
- Test & Measurement: Data loggers, precision instrumentation.
- Consumer Electronics: Audio processing, wearable health tech.
Its low power consumption, high accuracy, and multi-channel capability make it ideal for systems demanding reliable analog signal processing.
Package
The ADS131E08IPAGR is a 24-bit, 8-channel delta-sigma ADC. It comes in a TQFP-64 package (Thin Quad Flat Pack) with dimensions of 10x10mm and a 0.5mm pin pitch. This surface-mount package is suitable for high-precision analog applications, offering robust thermal and electrical performance.