AMC1302DWVR vs AMC1300DWV

對 AMC1302DWVR 和 AMC1300DWV 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AMC1302DWVR and AMC1300DWV are both isolated amplifiers in the same SOIC-8 (DWV) package with matching 5.0 V supply and industrial temperature ranges, making them strong functional replacement candidates. However, the AMC1302DWVR offers a ±50 mV input range with fixed gain of 41, while the AMC1300DWV provides a ±250 mV input range with fixed gain of 8.2, so the input signal range and gain must be validated against the target application before substitution.

Package Type High match
Supply Voltage High match
Input Voltage Range Validation required
Fixed Gain Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AMC1302DWVR AMC1300DWV Why it matters
Input Voltage Range ±50 mV ±250 mV Defines the differential signal span the isolated amplifier can accept; a ±50 mV device suits shunt-based current sensing with very low full-scale drop, while ±250 mV supports larger shunt voltages.
Fixed Gain 41 8.2 Determines the output-to-input scaling; the higher gain of the AMC1302 compensates for its smaller input range, so the two parts are not directly interchangeable without adjusting downstream scaling.
Input Offset Error (max) ±50 µV ±200 µV Offset error directly limits DC measurement accuracy; the lower offset of the AMC1302 provides better precision for low-level current sensing.
Input Offset Drift (max) ±0.5 µV/°C ±3 µV/°C Drift over temperature affects accuracy stability in real systems; the AMC1302 offers significantly better thermal stability of offset.
Gain Error (max) ±0.2% ±0.3% Gain error impacts the accuracy of the measured signal amplitude; tighter gain error improves overall measurement fidelity.
Gain Drift (max) ±40 ppm/°C ±45 ppm/°C Gain drift determines how much the scaling changes with temperature, affecting long-term accuracy in harsh environments.
Input Bandwidth (-3 dB) 280 kHz 310 kHz Bandwidth limits the maximum signal frequency the amplifier can faithfully pass; relevant for control-loop response and transient current sensing.
Isolation Rating (VISO) 5000 Vrms 5000 Vrms Reinforced isolation rating is critical for safety and noise immunity in high-voltage systems; both parts share the same rating here.
Supply Voltage (VDD1 / VDD2) 3.0–5.5 V / 3.0–5.5 V 3.0–5.5 V / 3.0–5.5 V Supply compatibility determines whether the part can drop into an existing rail scheme; identical ranges ease substitution from a power standpoint.
Package 8-SOIC (DWV) 8-SOIC (DWV) Package and pinout compatibility is essential for board-level substitutability; matching packages allow direct footprint reuse.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AMC1302DWVR AMC1300DWV
Supplier - Texas Instruments
Part Status Active Active
Type Isolation Isolation
Applications Current Sensing, Power Management Current Sensing, Power Management
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the AMC1302DWVR and the AMC1300DWV?

The AMC1302DWVR is a precision isolated amplifier with a ±50 mV input range optimized for shunt-based current sensing, while the AMC1300DWV is an isolated amplifier with a ±250 mV input range intended for similar current-sensing applications requiring a wider input span. Both are single-channel, reinforced-isolated amplifiers in the SOIC-8 (DWV) package, but they differ in input voltage range, gain, and specified linearity/offset performance per their respective datasheets.

Are the AMC1302DWVR and AMC1300DWV pin-compatible?

Yes. Both devices are offered in the same 8-pin SOIC (DWV) package with the same pinout (VDD1, INP, INN, GND1, VDD2, OUTP, OUTN, GND2), so they are pin-compatible and share the same PCB land pattern. Electrical differences must still be validated before substitution.

What input voltage range does each device support?

The AMC1302DWVR supports a linear input range of approximately ±50 mV, while the AMC1300DWV supports approximately ±250 mV. The choice depends on the shunt resistor value and the expected voltage drop across it in the target current-sensing design.

Do both devices provide reinforced isolation?

Yes. Both the AMC1302DWVR and AMC1300DWV are reinforced isolated amplifiers rated for 5 kV RMS isolation (per the manufacturer's isolation specifications) and are suitable for isolated current and voltage sensing in industrial and motor-drive applications. Designers should confirm the exact isolation ratings and certifications in the respective datasheets.

Can the AMC1302DWVR directly replace the AMC1300DWV in an existing design?

Not without validation. Although the devices are pin-compatible, the AMC1302DWVR has a smaller input range (±50 mV vs ±250 mV) and different gain and offset specifications. A direct swap changes the effective full-scale current measurement and may saturate the input, so the shunt value, gain, and signal chain must be re-evaluated against the datasheets.

What are the supply voltage requirements for these devices?

Both the AMC1302DWVR and AMC1300DWV operate with a high-side supply (VDD1) of 3.0 V to 5.5 V and a low-side supply (VDD2) of 3.0 V to 5.5 V, per the manufacturer datasheets. The isolated output is a differential signal referenced to GND2.

Which device is better suited for low-side shunt current sensing?

Both are suitable for shunt-based current sensing, but the AMC1302DWVR's ±50 mV input range allows use of a smaller shunt resistance and lower power dissipation for a given current, while the AMC1300DWV's ±250 mV range provides more headroom against noise and offset for larger shunt drops. Selection depends on the shunt value, current magnitude, and accuracy budget.