AFE58JD28ZAV
德州儀器
- Lifecycle
- Active
- Stock
- 7063 件
- Package
- NFBGA-289
- Series
- 資料獲取-類比前端(AFE)
對 AFE58JD28ZAV 和 AFE5816ZAV 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The AFE58JD28ZAV is a viable functional replacement candidate for the AFE5816ZAV, sharing the same 8-channel ultrasound AFE architecture, 14-bit ADC resolution, and 16 mm × 16 mm NFBGA-289 footprint. Designers must validate the higher per-channel power consumption and the extended operating temperature range against the target system's thermal and environmental requirements before committing to a drop-in substitution.
德州儀器
德州儀器
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE58JD28ZAV | AFE5816ZAV |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 12, 14 | 12, 14 |
| Number of Channels | 16 | 16 |
| Power (Watts) | 64 mW | 94 mW |
| Voltage - Supply, Analog | 3.15V ~ 3.6V | 1.7V ~ 2V, 3V ~ 3.3V |
| Mounting Type | Surface Mount | Surface Mount |
| Voltage - Supply, Digital | - | 1.15V ~ 1.25V, 1.7V ~ 1.9V |
The AFE5816ZAV and AFE58JD28ZAV are both Texas Instruments fully integrated analog front-end (AFE) devices for ultrasound imaging systems. Each integrates a low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), anti-aliasing filter, and a 14-bit analog-to-digital converter (ADC) across multiple channels in a single package.
The AFE5816ZAV integrates 16 channels, while the AFE58JD28ZAV integrates 8 channels. This difference directly affects the number of transducer elements each device can support and the overall system partitioning in an ultrasound front end.
Both devices are offered in a 289-ball NFBGA (ZAV) package. However, because the AFE5816ZAV provides 16 channels and the AFE58JD28ZAV provides 8 channels, the pin functions and channel-to-ball assignments differ, so the two are not pin-for-pin drop-in replacements despite sharing the same package outline.
Both the AFE5816ZAV and AFE58JD28ZAV incorporate a 14-bit ADC with a maximum sampling rate of 65 MSPS per channel, supporting the bandwidth and dynamic range requirements typical of medical ultrasound receive chains.
Because the AFE5816ZAV integrates 16 channels and the AFE58JD28ZAV integrates 8 channels, total power scales with channel count. Per-channel power consumption is comparable between the two devices, so the 16-channel AFE5816ZAV dissipates roughly twice the total power of the 8-channel AFE58JD28ZAV under equivalent per-channel operating conditions.
No, they are not direct substitutes. The AFE58JD28ZAV provides only 8 channels versus 16 channels in the AFE5816ZAV, and the channel-to-ball assignments differ within the shared 289-ball NFBGA package. A substitution would require redesign of the channel mapping, PCB layout, and system partitioning, validated against the respective TI datasheets.
Both devices provide a low-voltage differential signaling (LVDS) digital output interface for the 14-bit ADC data, supporting high-speed serial data transfer to an FPGA or digital signal processor in the ultrasound receive path.