ADS1282IPWR
德州儀器
- Lifecycle
- Active
- Stock
- 3098 件
- Package
- TSSOP-28
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1282IPWR 和 ADS1208IPWR 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1282IPWR and ADS1208IPWR are not drop-in replacements for one another. The ADS1282IPWR is a high-resolution 32-bit delta-sigma ADC with an integrated PGA and low-noise architecture intended for seismic and precision sensor acquisition, while the ADS1208IPWR is a 16-bit second-order delta-sigma modulator with a current-shunt input stage intended for isolated current-sense and motor-control feedback. They differ in resolution, input architecture, output interface, and package pinout, so a direct substitution is not feasible without a full system redesign.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1282IPWR | ADS1208IPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 31 | 16 | Resolution determines the smallest signal change the ADC can distinguish; a 31-bit delta-sigma converter offers far finer measurement precision than a 16-bit device. |
| Architecture | Delta-Sigma (2nd order) | Delta-Sigma (2nd order) | Both use delta-sigma modulation, but the ADS1282 is a high-resolution seismic-grade converter while the ADS1208 is a lower-resolution isolated-modulator style device, affecting noise and application fit. |
| Input type | Differential | Differential | Differential inputs reject common-mode noise; both share this, but the ADS1282 supports a wider analog input range suited to direct sensor connection. |
| Data rate / output rate | Up to 4 kSPS | Up to 40 kSPS | Output data rate sets the trade-off between speed and noise; the ADS1208 offers higher throughput while the ADS1282 targets lower-speed, high-precision measurements. |
| Supply voltage | 2.7 V to 5.25 V (analog), 1.8 V to 3.6 V (digital) | 4.5 V to 5.5 V | Supply requirements determine power-rail compatibility; the ADS1282 supports lower and split rails, while the ADS1208 needs a 5 V supply. |
| Interface | SPI (serial) | SPI (serial) | Both use a serial SPI interface, but register maps and command sets differ, so firmware is not directly interchangeable. |
| Package | TSSOP-28 | TSSOP-16 | Package footprint and pin count affect PCB layout and drop-in compatibility; the two devices are not pin-compatible. |
| Operating temperature range | -40 °C to +85 °C | -40 °C to +85 °C | Both cover the industrial temperature range, so environmental tolerance is comparable for most applications. |
| Typical application focus | Seismic, energy exploration, high-resolution sensor measurement | Motor control, current sensing, isolated signal conditioning | Intended use cases differ significantly, so functional substitutability is limited even where electrical specs overlap. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1282IPWR | ADS1208IPWR |
|---|---|---|
| Supplier | - | Texas Instruments,Rochester Electronics, LLC |
| Part Status | Active | Obsolete |
| Type | - | Modulator |
| Number of Channels | - | 1 |
| Resolution(Bits) | - | 16 b |
| Sampling Rate(Per Second) | 4k | 40k |
| Data Interface | SPI | Serial |
| Voltage Supply Source | - | Analog and Digital |
| Voltage - Supply | - | 2.7V ~ 5.5V, 4.5V ~ 5.5V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | - | Surface Mount |
| Number of Bits | 31 | - |
| Number of Inputs | 1 | - |
| Input Type | Differential | - |
| Configuration | ADC | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External | - |
| Voltage - Supply, Analog | 5V | - |
| Voltage - Supply, Digital | 1.65V ~ 3.6V | - |
| Features | PGA | - |
The ADS1282IPWR is a high-resolution, 32-bit delta-sigma analog-to-digital converter (ADC) designed for seismic and energy exploration applications, featuring a programmable gain amplifier (PGA) and offering data rates up to 4 kSPS. The ADS1208IPWR is a 16-bit, second-order delta-sigma modulator with a digital filter, intended for isolated current and voltage sensing in motor control and power measurement, providing a 10 MHz master clock and a 78.1 kSPS output data rate. They differ fundamentally in resolution, architecture, and target application.
No. The ADS1282IPWR is supplied in a 28-pin TSSOP package, while the ADS1208IPWR is supplied in a 16-pin TSSOP package. The pin counts and pin functions differ, so they are not pin-to-pin compatible and cannot be interchanged on the same PCB footprint without redesign.
No, their supply requirements differ. The ADS1282IPWR operates from an analog supply of 5 V (AVDD) and a digital supply of 1.8 V to 3.3 V (DVDD). The ADS1208IPWR operates from a single 5 V supply (AVDD and DVDD both at 5 V). Designers must verify the supply rails against each device's datasheet before considering either part.
The ADS1282IPWR offers 32-bit resolution, whereas the ADS1208IPWR provides 16-bit resolution. The higher resolution of the ADS1282IPWR supports finer signal discrimination in low-frequency, high-dynamic-range applications such as seismic data acquisition, while the ADS1208IPWR's 16-bit resolution is suited to isolated current and voltage sensing in motor and power control loops.
No. The ADS1282IPWR includes an integrated PGA with selectable gains of 1, 2, 4, 8, 16, 32, and 64, allowing direct connection of low-level sensors. The ADS1208IPWR does not include a PGA; it is a modulator intended to be paired with external signal conditioning and isolation circuitry.
The ADS1282IPWR supports programmable data rates up to 4 kSPS. The ADS1208IPWR provides a fixed output data rate of 78.1 kSPS when using a 10 MHz master clock. These rates reflect their different application targets: high-resolution low-speed sensing versus higher-speed isolated measurement.
No. Because they differ in package, pin count, supply voltage, resolution, integrated features (PGA vs. modulator-only architecture), and output data rate, the two devices are not interchangeable. Any substitution requires a full review of the schematic, PCB layout, power supply, and digital interface against the respective manufacturer datasheets.