對 ADS1281IPWR 和 ADS1282IPW 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADS1281IPWR is a functionally compatible replacement candidate for the ADS1282IPW, sharing the same 24-bit delta-sigma ADC core, TSSOP-28 footprint, and industrial temperature range, though the ADS1282IPW adds an integrated PGA and requires validation of the differing input architecture and power consumption in the target application.

Resolution and ADC Architecture High match
Package and Pin Footprint High match
Input Configuration Validation required
Power Consumption Validation required

Parts at a glance

Part B

ADS1282IPW

德州儀器

Lifecycle
Active
Stock
4636 件
Package
TSSOP-28
Series
資料獲取-模數轉換器(ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1282IPW ADS1281IPWR Why it matters
Resolution (bits) 31 31 Both are 31-bit delta-sigma ADCs, so resolution is equivalent for high-precision measurement applications.
Number of Input Channels 2 (differential) 1 (differential) The ADS1282 provides two differential inputs (with an input multiplexer), while the ADS1281 has a single differential input; this affects multi-sensor designs.
Input Multiplexer Yes (2-channel MUX) No An integrated MUX allows switching between multiple signal sources without external components, simplifying system design.
PGA / Gain Stages Yes (low-noise PGA) No The ADS1282 includes a programmable gain amplifier for direct connection of low-level sensors, whereas the ADS1281 requires external signal conditioning.
Data Output Rate (max SPS) 4000 SPS 4000 SPS Both support up to 4000 samples per second, suitable for seismic and precision industrial measurement.
Supply Voltage (analog) 5 V (analog), 3.3 V (digital) 5 V (analog), 3.3 V (digital) Identical supply requirements allow the same power rail design for either part.
Package TSSOP-28 TSSOP-24 Different pin counts and footprints mean the PCB layout must be redesigned; the parts are not drop-in footprint compatible.
Operating Temperature Range -40°C to +85°C -40°C to +85°C Both cover the industrial temperature range, so environmental suitability is equivalent.
Interface SPI (serial) SPI (serial) Both use a compatible SPI interface, easing digital-side integration for either device.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1281IPWR ADS1282IPW
Part Status Active Active
Number of Bits 31 31
Sampling Rate(Per Second) 4k 4k
Number of Inputs 1 1
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 1.65V ~ 3.6V 1.65V ~ 3.6V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Features - PGA

Frequently asked questions

What are the key differences between the ADS1282IPW and ADS1281IPWR?

The ADS1282IPW is a 31-bit delta-sigma ADC with an integrated programmable gain amplifier (PGA) and two-channel input multiplexer, while the ADS1281IPWR is a 31-bit delta-sigma ADC without an integrated PGA or input multiplexer. Both are single-channel ADCs from Texas Instruments in a TSSOP-28 package, but the ADS1282 includes a PGA (gains of 1, 2, 4, 8, 16, 32, 64) and a 2:1 input MUX, whereas the ADS1281 provides a fixed-gain signal path without these features.

Are the ADS1282IPW and ADS1281IPWR pin-compatible?

No. Although both devices are offered in a 28-pin TSSOP package, their pin functions differ because the ADS1282IPW includes PGA and multiplexer control pins that the ADS1281IPWR does not. A direct drop-in replacement is not possible without verifying pin functions and PCB layout against the respective datasheets.

Do both devices share the same resolution and data rate specifications?

Both are 31-bit delta-sigma ADCs. The ADS1282IPW supports data rates from 250 SPS to 4 kSPS, and the ADS1281IPWR supports data rates from 250 SPS to 4 kSPS as well. Both target high-resolution seismic and energy exploration applications, but the ADS1282IPW adds PGA and MUX functionality that affects the effective input range and configuration.

Can the ADS1281IPWR be used as a substitute for the ADS1282IPW in an existing design?

Not directly. Because the ADS1282IPW integrates a PGA and a two-channel input multiplexer that the ADS1281IPWR lacks, substituting the ADS1281IPWR would require external signal conditioning and rework of the input stage. The substitution should only be made after validating the signal chain, pin functions, and firmware configuration against the ADS1281IPWR datasheet.

What are the package and ordering differences between ADS1282IPW and ADS1281IPWR?

Both parts are supplied in a 28-pin TSSOP package. The ADS1282IPW is typically ordered in tube format, while the ADS1281IPWR suffix indicates tape-and-reel packaging. The "I" grade in both part numbers denotes the industrial temperature range of -40°C to +85°C.

Which device is better suited for multi-sensor seismic acquisition systems?

The ADS1282IPW is generally more suitable for multi-sensor acquisition because its integrated two-channel input multiplexer allows switching between two sensor inputs without external multiplexing hardware, and its PGA supports direct interfacing with geophones of varying sensitivity. The ADS1281IPWR is better suited to single-sensor channels where a fixed input configuration is acceptable.

Do both ADCs support the same digital interface and reference configuration?

Both devices provide a serial peripheral interface (SPI)-compatible digital interface and support differential reference inputs. However, register maps and configuration commands differ because the ADS1282IPW includes PGA and MUX control registers that the ADS1281IPWR does not. Firmware must be adapted accordingly when migrating between the two devices.