ADS1282IPW vs ADS1232IPWRG4

對 ADS1282IPW 和 ADS1232IPWRG4 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1282IPW and ADS1232IPWRG4 are not drop-in replacements for one another. Although both are 24-bit delta-sigma ADCs, they differ fundamentally in resolution architecture, input configuration, package footprint, and target application class, so substituting one for the other requires full electrical and mechanical redesign validation.

Different input architecture Different package footprint Different data rate range Different supply requirements

Parts at a glance

Part A

ADS1282IPW

德州儀器

Lifecycle
Active
Stock
4636 件
Package
TSSOP-28
Series
資料獲取-模數轉換器(ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1282IPW ADS1232IPWRG4 Why it matters
Resolution (bits) 31 24 Higher resolution enables finer measurement of small signal changes, which is critical for precision sensor and seismic applications.
Architecture Delta-Sigma (2nd order) Delta-Sigma The modulator architecture affects noise shaping, linearity, and achievable effective resolution for the target signal bandwidth.
Number of Input Channels 2 (differential) 2 (differential) Channel count determines how many independent differential signals can be digitized without external multiplexing.
Maximum Data Rate (SPS) 4000 80 The output data rate bounds the signal bandwidth and settling time achievable in the application.
PGA / Gain Stages 1, 2, 4, 8, 16, 32, 64 1, 2, 64, 128 Available gain settings determine the smallest input signal that can be amplified to full scale, affecting low-level measurement capability.
Supply Voltage (analog) 5 V (analog), 3.3 V (digital) 2.7 V to 5.3 V Supply requirements affect power rail design and compatibility with the host system's available voltages.
Interface SPI (serial) SPI (serial) The digital interface must match the host controller's supported protocol for direct connection.
Package TSSOP-28 TSSOP-24 Package footprint and pin count affect PCB layout and whether a drop-in replacement is possible.
Operating Temperature Range -40°C to +85°C -40°C to +105°C The temperature range determines suitability for industrial and harsh-environment deployments.
Typical Application Focus Seismic, energy exploration, precision industrial Weigh scales, strain gauges, pressure sensors The intended application focus indicates whether noise, linearity, and speed characteristics match the target use case.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1282IPW ADS1232IPWRG4
Supplier - Texas Instruments
Part Status Active Discontinued at Digi-Key
Number of Bits 31 24
Sampling Rate(Per Second) 4k 80
Number of Inputs 1 2
Input Type Differential Differential, Single Ended
Data Interface SPI SPI
Configuration ADC MUX-PGA-ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 5V 2.7V ~ 5.3V
Voltage - Supply, Digital 1.65V ~ 3.6V 2.7V ~ 5.3V
Features PGA PGA
Operating Temperature -40°C ~ 85°C -40°C ~ 105°C

Frequently asked questions

What are the primary functional differences between the ADS1282IPW and ADS1232IPWRG4?

The ADS1282IPW is a single-channel, 31-bit delta-sigma ADC designed for high-resolution seismic and energy exploration applications, featuring a programmable gain amplifier (PGA) and selectable data rates up to 4 kSPS. The ADS1232IPWRG4 is a dual-channel, 24-bit delta-sigma ADC intended for weigh scales and pressure sensors, offering a fixed gain of 1 or 128 and data rates of 10 SPS or 80 SPS. They differ in resolution, channel count, gain architecture, and target application.

Are the ADS1282IPW and ADS1232IPWRG4 pin-compatible or package-compatible?

No. The ADS1282IPW is supplied in a 28-pin TSSOP (PW) package, while the ADS1232IPWRG4 is supplied in a 24-pin TSSOP (PW) package. The pin counts and pin functions differ, so they are not drop-in replacements and require different PCB land patterns.

What are the supply voltage requirements for each device?

The ADS1282IPW operates from an analog supply (AVDD) of 4.75 V to 5.25 V and a digital supply (DVDD) of 1.8 V to 3.6 V. The ADS1232IPWRG4 operates from a single supply of 2.7 V to 5.3 V (AVDD and DVDD tied together in typical configurations). Designs must account for these differing supply architectures.

How do the data output rates compare between the two ADCs?

The ADS1282IPW supports programmable output data rates from 250 SPS to 4 kSPS in its standard operating modes. The ADS1232IPWRG4 provides two selectable data rates: 10 SPS and 80 SPS. The ADS1282IPW is therefore suited to higher-bandwidth signal acquisition, while the ADS1232IPWRG4 targets low-frequency, high-resolution measurement such as weigh scales.

Do both devices include a programmable gain amplifier (PGA)?

Yes, but with different architectures. The ADS1282IPW includes a PGA with selectable gains of 1, 2, 4, 8, 16, 32, and 64. The ADS1232IPWRG4 provides a fixed gain of 128 on its input channel (with a gain of 1 bypass path), optimized for low-level bridge sensor signals. The gain flexibility differs significantly between the two parts.

What are the typical target applications for each device?

The ADS1282IPW is intended for high-resolution seismic data acquisition, energy exploration, and precision industrial measurement requiring wide dynamic range and higher sample rates. The ADS1232IPWRG4 is intended for weigh scales, strain gauge and pressure sensor interfaces, and other low-frequency bridge-sensor applications. Application requirements should guide selection between them.

Can the ADS1232IPWRG4 directly replace the ADS1282IPW in an existing design?

No. The devices differ in package pin count (24 vs 28 pins), supply requirements, resolution (24-bit vs 31-bit), channel count (dual vs single), gain architecture, and data rate range. A direct replacement is not possible without redesigning the PCB, supply, and firmware configuration, and validating performance against the target specification.