ADS1271IBPWR vs ADS1286UB/2K5

對 ADS1271IBPWR 和 ADS1286UB/2K5 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1271IBPWR and ADS1286UB/2K5 are not drop-in replacements for one another. They differ in resolution, architecture, sample rate, and package, so substituting one for the other requires a full redesign of the surrounding signal chain and layout rather than a direct swap.

Different resolution Different architecture Different sample rate Different package

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1271IBPWR ADS1286UB/2K5 Why it matters
Resolution (bits) 24 12 Resolution determines the smallest signal change the ADC can distinguish; a 24-bit converter offers far finer quantization than a 12-bit one, so they are not functionally interchangeable for high-dynamic-range measurements.
Architecture Delta-Sigma SAR Delta-sigma and SAR architectures differ fundamentally in noise shaping, latency, and oversampling behavior, affecting suitability for precision DC versus fast multiplexed acquisition.
Sample Rate (max) 105 kSPS 20 kSPS Maximum throughput limits how fast signals can be digitized; the higher-rate part supports wider-bandwidth or faster-cycling applications.
Input Type Differential Single-ended Differential inputs reject common-mode noise and improve accuracy in noisy environments, while single-ended inputs simplify wiring but are more susceptible to ground noise.
Supply Voltage 5 V (analog), 1.8 V to 3.3 V (digital) 5 V Supply requirements determine power-rail compatibility; the dual-supply device allows low-voltage digital interfacing while the single-supply device needs a 5 V rail.
Interface SPI (serial) SPI (serial) Both use a serial SPI interface, so host-side protocol compatibility is similar, though timing and frame formats must still be verified.
Package TSSOP-16 SOIC-8 Package footprint and pin count affect PCB layout and drop-in compatibility; different packages require board redesign.
Operating Temperature Range -40 °C to +105 °C -40 °C to +85 °C The wider temperature range of one part supports harsher industrial environments where the other may exceed its rated limits.
Power Consumption (typical) ~70 mW ~2.5 mW Power dissipation impacts thermal design and battery life; the SAR device is far more power-efficient, which matters for portable or low-power systems.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1271IBPWR ADS1286UB/2K5
Supplier - Texas Instruments
Part Status Active Obsolete
Number of Bits 24 12
Sampling Rate(Per Second) 105k 20k
Number of Inputs 1 1
Input Type Differential Differential
Data Interface SPI SPI
Configuration ADC S/H-ADC
Ratio - S / H: ADC - 1:1
Number of A/D Converters 1 1
Architecture Sigma-Delta SAR
Reference Type External External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 1.65V ~ 3.6V 5V
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C

Frequently asked questions

What are the primary differences between the ADS1271IBPWR and the ADS1286UB/2K5?

The ADS1271IBPWR is a 24-bit, 105 kSPS delta-sigma ADC with a wide analog supply range (4.75 V to 5.25 V) and a digital supply range of 1.65 V to 3.6 V, housed in a TSSOP-16 package. The ADS1286UB/2K5 is a 12-bit, 200 kSPS successive-approximation register (SAR) ADC with a 5 V single supply, housed in a SOIC-8 package. They differ in resolution, architecture, sampling rate, supply requirements, and package footprint.

Are the ADS1271IBPWR and ADS1286UB/2K5 pin-to-pin or package compatible?

No. The ADS1271IBPWR uses a TSSOP-16 package, while the ADS1286UB/2K5 uses a SOIC-8 package. The pin counts, pin functions, and PCB land patterns are different, so they are not directly interchangeable without a board redesign.

Can the ADS1271IBPWR and ADS1286UB/2K5 be used in the same application interchangeably?

No. The ADS1271IBPWR offers 24-bit resolution at up to 105 kSPS with a delta-sigma architecture, suitable for high-resolution precision measurement. The ADS1286UB/2K5 offers 12-bit resolution at up to 200 kSPS with a SAR architecture, suitable for faster, lower-resolution conversions. Their resolution, speed, and interface characteristics differ, so they target different application requirements.

What are the supply voltage requirements for each device?

The ADS1271IBPWR requires an analog supply (AVDD) of 4.75 V to 5.25 V and a digital supply (DVDD) of 1.65 V to 3.6 V. The ADS1286UB/2K5 operates from a single 5 V supply. Designs must account for these different supply configurations.

How do the sampling rates and resolution of the two ADCs compare?

The ADS1271IBPWR provides 24-bit resolution with a maximum data rate of 105 kSPS. The ADS1286UB/2K5 provides 12-bit resolution with a maximum sampling rate of 200 kSPS. The ADS1271IBPWR prioritizes resolution, while the ADS1286UB/2K5 prioritizes speed.

Do the ADS1271IBPWR and ADS1286UB/2K5 use the same digital interface?

No. The ADS1271IBPWR provides a serial interface (SPI-compatible) for data output. The ADS1286UB/2K5 also provides a serial interface, but the frame format, word length, and timing differ due to the different resolution and architecture. Firmware and interface logic must be adapted accordingly.

What are the typical application differences between the ADS1271IBPWR and ADS1286UB/2K5?

The ADS1271IBPWR is typically used in high-resolution precision measurement applications such as industrial process control, weigh scales, and medical instrumentation. The ADS1286UB/2K5 is typically used in faster, lower-resolution applications such as data acquisition systems, motor control, and general-purpose monitoring where 12-bit resolution is sufficient.