The ADS1260BIRHBR and ADS1283IRHFR are both high-resolution delta-sigma ADCs, but they differ fundamentally in resolution, input architecture, package footprint, and target application domain. The ADS1260BIRHBR offers 32-bit resolution with a flexible multiplexed input and integrated PGA, while the ADS1283IRHFR is a 31-bit seismic-grade converter with a fixed differential input and different pinout. These differences prevent direct substitution without redesign of the signal chain, layout, and firmware configuration.

Different resolution class Different input architecture Different package footprint Different application domain

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1260BIRHBR ADS1283IRHFR Why it matters
Resolution (bits) 32 31 Resolution determines the smallest signal change the ADC can resolve; a 32-bit vs 31-bit difference affects dynamic range and low-level measurement capability.
Number of input channels 5 (4 differential / 5 single-ended) 2 (1 differential) Channel count determines how many sensors or signal sources can be multiplexed into a single ADC, directly affecting system architecture and BOM cost.
Maximum sample rate 40 kSPS 4 kSPS Sample rate sets the bandwidth of signals that can be captured; a 10x difference impacts suitability for high-frequency or fast transient measurements.
Input type / architecture Delta-sigma with integrated PGA Delta-sigma with integrated PGA Both use delta-sigma conversion with a PGA, but the ADS1260 offers more flexible multiplexing while the ADS1283 targets seismic/energy exploration with very low noise.
Interface SPI SPI Both use SPI, so host microcontroller compatibility is similar, though register maps and command sets differ and require firmware changes.
Supply voltage (analog) 5 V (analog), 3.3 V (digital) 5 V (analog), 3.3 V (digital) Matching supply rails simplifies power design, but the two parts still differ in internal reference and bias requirements.
Package VQFN-40 (6x6 mm) VQFN-24 (5x4 mm) Different package footprints and pin counts mean the two parts are not drop-in compatible and require separate PCB layouts.
Operating temperature range -40°C to +125°C -40°C to +85°C The wider temperature range of the ADS1260 supports harsher industrial environments, while the ADS1283 is limited to standard industrial conditions.
Target application focus Precision industrial sensor and process control Seismic and energy exploration data acquisition Different design optimizations (noise, bandwidth, channel count) mean the parts are not functionally interchangeable despite both being high-resolution delta-sigma ADCs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1260BIRHBR ADS1283IRHFR
Part Status Active Active
Number of Bits 24 31
Sampling Rate (Per Second) 40k 128k
Number of Inputs 5 2
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration MUX-PGA-ADC MUX-PGA-ADC
Ratio - S / H: ADC - 0:1
Number of A / D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External, Internal External
Voltage - Supply, Analog 4.75V ~ 5.25V 2.15V ~ 5.25V
Voltage - Supply, Digital 2.7V ~ 5.25V 1.65V ~ 3.6V
Features PGA PGA
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Base Product Number ADS1260 ADS1283
Packaging Cut Tape (CT), Tape & Reel (TR) -

Frequently asked questions

What are the primary differences between the ADS1260BIRHBR and the ADS1283IRHFR?

The ADS1260BIRHBR is a 32-bit, 40-kSPS delta-sigma ADC with an integrated PGA, reference, and oscillator, housed in a 5-mm × 5-mm VQFN-32 package. The ADS1283IRHFR is a 32-bit, 125-SPS delta-sigma ADC optimized for seismic and energy-exploration applications, featuring a low-noise PGA and housed in a 5-mm × 5-mm VQFN-24 package. The ADS1260B targets general-purpose high-resolution industrial sensing, while the ADS1283 targets high-resolution, low-frequency seismic and geophysical data acquisition.

Are the ADS1260BIRHBR and ADS1283IRHFR pin-to-pin or package compatible?

No. The ADS1260BIRHBR uses a VQFN-32 package, while the ADS1283IRHFR uses a VQFN-24 package. The pin counts, pin functions, and PCB land patterns differ, so the two devices are not drop-in replacements and require separate board layouts.

How do the maximum output data rates of the ADS1260BIRHBR and ADS1283IRHFR compare?

The ADS1260BIRHBR supports output data rates up to 40 kSPS in its fastest configuration. The ADS1283IRHFR supports output data rates up to 125 SPS. The ADS1260B is therefore suited to higher-speed multiplexed industrial measurements, while the ADS1283 is intended for low-frequency, high-resolution seismic and geophysical acquisition.

Do both devices include an integrated programmable gain amplifier (PGA)?

Yes. Both the ADS1260BIRHBR and the ADS1283IRHFR integrate a low-noise programmable gain amplifier. The ADS1260B PGA supports gains from 1 to 32, while the ADS1283 PGA supports gains of 1, 2, 4, 8, 16, 32, and 64, allowing direct interface to low-level sensors such as geophones and hydrophones.

What are the typical target applications for the ADS1260BIRHBR versus the ADS1283IRHFR?

The ADS1260BIRHBR is intended for high-resolution industrial measurement, process control, test and measurement, and precision sensor interfaces requiring data rates up to 40 kSPS. The ADS1283IRHFR is intended for seismic data acquisition, energy exploration, and other low-frequency, high-dynamic-range geophysical applications requiring data rates up to 125 SPS.

Do the ADS1260BIRHBR and ADS1283IRHFR share the same supply voltage requirements?

Both devices operate from an analog supply of 5 V and a digital supply of 3.3 V (with 1.8 V to 3.3 V digital I/O options on the ADS1283). Designers should confirm exact supply ranges and decoupling requirements against the respective manufacturer datasheets before finalizing a design.

Can the ADS1283IRHFR be used as a direct replacement for the ADS1260BIRHBR in an existing design?

No. Because the two devices differ in package (VQFN-24 versus VQFN-32), pinout, maximum data rate (125 SPS versus 40 kSPS), PGA gain options, and register map, a direct replacement is not possible. Any substitution requires a new PCB layout and firmware changes validated against the target device datasheet.