ADS124S06IPBS
德州儀器
- Lifecycle
- Active
- Stock
- 2820 件
- Package
- TQFP-32
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS124S06IPBS 和 ADS1296IPAGR 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS124S06IPBS and ADS1296IPAGR are not drop-in replacements for one another. The ADS124S06IPBS is a 6-channel, 24-bit precision delta-sigma ADC with a single unipolar/bipolar supply and no integrated front-end, while the ADS1296IPAGR is a 6-channel, 24-bit biopotential front-end with integrated PGAs, internal reference, and ECG/EEG-specific features. Their pinouts, package footprints, supply architectures, and functional integration differ substantially, so a direct board-level substitution is not possible without redesign.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS124S06IPBS | ADS1296IPAGR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma ADCs, so nominal resolution is equivalent for precision measurement applications. |
| Number of input channels | 6 (single-ended) / 3 (differential) | 8 (differential) | Channel count determines how many signals can be digitized simultaneously; the ADS1296 offers more differential inputs for multi-lead biopotential sensing. |
| Typical application focus | Precision sensor measurement (temperature, pressure, strain) | Biopotential / ECG / EEG signal acquisition | The intended application domain affects integrated features such as input bias, lead-off detection, and reference architecture, impacting functional substitutability. |
| Programmable gain amplifier (PGA) gain range | 1 to 128 | 1 to 12 | A wider PGA range allows the ADS124S06 to resolve smaller sensor signals directly, while the ADS1296 gain range is tailored to biopotential amplitudes. |
| Data output rate (max SPS) | 4 kSPS | 32 kSPS | Maximum sample rate limits the bandwidth of signals that can be captured; the ADS1296 supports higher throughput for multi-channel biopotential sampling. |
| Supply voltage (analog) | 2.7 V to 5.25 V (single supply) | 2.7 V to 5.25 V (analog) with unipolar/bipolar options | Supply compatibility affects whether the part can drop into an existing rail architecture without additional regulation. |
| Integrated features | PGA, internal reference, IDAC, sensor excitation | PGA, internal reference, lead-off detection, respiration impedance, pace detection | On-chip feature sets differ substantially; the ADS1296 integrates biopotential-specific functions not present on the ADS124S06, limiting direct substitution. |
| Package | TQFP-32 (PBS) | TQFP-64 (PAG) | Different package footprints and pin counts prevent pin-compatible board-level replacement between the two devices. |
| Interface | SPI | SPI | Both use SPI, so host-side digital communication protocol is compatible, though register maps and command sets differ. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS124S06IPBS | ADS1296IPAGR |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | 24 | 24 |
| Number of Channels | - | 6 |
| Power (Watts) | - | 17.5 mW |
| Voltage - Supply, Analog | 2.7V ~ 5.25V | 2.7V ~ 5.5V |
| Voltage - Supply, Digital | 2.7V ~ 3.6V | 1.65V ~ 3.6V |
| Mounting Type | - | Surface Mount |
| Sampling Rate(Per Second) | 4k | - |
| Number of Inputs | 6 | - |
| Input Type | Single Ended | - |
| Data Interface | SPI | - |
| Configuration | MUX-PGA-ADC | - |
| Ratio - S / H: ADC | 0:1 | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External, Internal | - |
| Features | PGA | - |
| Operating Temperature | -50°C ~ 125°C | - |
The ADS124S06IPBS is a 24-bit, 6-channel delta-sigma ADC designed for precision sensor measurement, while the ADS1296IPAGR is a 24-bit, 6-channel simultaneous-sampling delta-sigma ADC with integrated ECG/EEG front-end features, including programmable gain amplifiers and lead-off detection, intended for biopotential measurement applications.
No. The ADS124S06IPBS is supplied in a 32-pin TQFP package, and the ADS1296IPAGR is supplied in a 64-pin TQFP package. The pin counts and pin functions differ, so they are not pin-to-pin compatible.
No. Differences in package footprint, pinout, channel architecture, integrated features, and typical application targets mean the two devices are not direct substitutes. Any replacement requires schematic, layout, and firmware validation against the respective manufacturer datasheets.
The ADS124S06IPBS provides 6 single-ended or 3 differential input channels with a flexible input multiplexer. The ADS1296IPAGR provides 6 simultaneous-sampling differential input channels, each with its own PGA and ADC, enabling correlated multi-channel acquisition.
The ADS124S06IPBS is generally the more appropriate choice for precision industrial sensor measurement, as it is specified for low-noise, high-resolution measurement of signals such as RTDs, thermocouples, and bridge sensors, with integrated features such as a programmable gain amplifier and excitation current sources.
The ADS1296IPAGR is intended for biopotential applications. It integrates six simultaneous-sampling 24-bit ADCs with PGAs and supports features such as lead-off detection and respiration measurement, which are relevant to ECG and EEG front-end designs.
Yes. Both the ADS124S06IPBS and the ADS1296IPAGR provide an SPI-compatible serial interface for configuration and data readout, as documented in their respective manufacturer datasheets.
Not directly. Although both are 24-bit delta-sigma ADCs, the ADS1296IPAGR has a different package, pinout, channel architecture, and feature set optimized for biopotential acquisition. A replacement would require redesign and validation rather than a direct drop-in substitution.