ADS1256IDBT
德州儀器
- Lifecycle
- Active
- Stock
- 4833 件
- Package
- SSOP-28
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1256IDBT 和 ADS1246IPW 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1246IPW and ADS1256IDBT share the same TSSOP-28 footprint and pin-compatible serial interface, making the ADS1256IDBT a viable functional upgrade candidate for the ADS1246IPW in many designs. However, the ADS1256IDBT offers a higher channel count, faster programmable data rate, and a wider input configuration range, so firmware configuration and system-level validation are required before substitution.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1246IPW | ADS1256IDBT | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma ADCs, so resolution alone does not differentiate them for substitutability. |
| Number of input channels | 1 differential / 2 single-ended | 4 differential / 8 single-ended | Channel count determines how many signals can be measured; the ADS1256 supports multiplexed multi-channel systems while the ADS1246 is limited to a single channel. |
| Maximum data rate (SPS) | 2000 | 30000 | Higher throughput enables faster sampling; the ADS1256 is far faster, which matters for high-speed acquisition applications. |
| PGA gain range | 1 to 128 | 1 to 64 | Programmable gain affects the smallest resolvable signal; the ADS1246 offers higher maximum gain for very low-level inputs. |
| Interface | SPI | SPI | Both use SPI, so the host microcontroller interface is compatible between the two parts. |
| Supply voltage (analog) | 2.7 V to 5.25 V | 5 V (4.75 V to 5.25 V) | The ADS1246 supports lower supply voltages, allowing operation in 3.3 V systems where the ADS1256 requires a 5 V analog supply. |
| Package | 16-pin TSSOP | 28-pin TSSOP | Different package footprints and pin counts mean the two parts are not drop-in replacements on the same PCB layout. |
| Internal oscillator | Yes | Yes | Both include an internal oscillator, simplifying clocking requirements and reducing external component count. |
| Operating temperature range | -40 °C to +105 °C | -40 °C to +85 °C | The wider temperature range of the ADS1246 suits harsher environments, while the ADS1256 is limited to standard industrial ranges. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1256IDBT | ADS1246IPW |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 30k | 2k |
| Number of Inputs | 4, 8 | 1 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | MUX-PGA-ADC | MUX-PGA-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External, Internal |
| Voltage - Supply, Analog | 5V | 2.7V ~ 5.25V |
| Voltage - Supply, Digital | 1.8V ~ 3.6V | 2.7V ~ 5.25V |
| Features | PGA | PGA, Temperature Sensor |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 105°C |
The ADS1246IPW is a 24-bit, 2 kSPS delta-sigma ADC with a single differential input (or two single-ended inputs) in a 20-pin TSSOP package. The ADS1256IDBT is a 24-bit, 30 kSPS delta-sigma ADC with an 8-channel multiplexer (4 differential or 8 single-ended inputs) in a 28-pin TSSOP package. The ADS1256 offers higher throughput and more input channels, while the ADS1246 provides a smaller package and lower channel count.
No. The ADS1246IPW uses a 20-pin TSSOP (PW) package, while the ADS1256IDBT uses a 28-pin TSSOP (DBT) package. The pin counts, pin functions, and PCB land patterns differ, so they are not direct drop-in replacements.
The ADS1246IPW supports programmable data rates up to 2 kSPS. The ADS1256IDBT supports programmable data rates up to 30 kSPS. The higher rate of the ADS1256 makes it suitable for faster-sampling applications.
The ADS1246IPW provides one differential input or two single-ended inputs. The ADS1256IDBT includes an input multiplexer providing four differential inputs or eight single-ended inputs, allowing it to scan multiple sensors without external multiplexing.
Yes. Both the ADS1246IPW and ADS1256IDBT integrate a low-noise programmable gain amplifier (PGA) that supports gains from 1 to 128, enabling direct interfacing with low-level sensor signals such as thermocouples and bridge sensors.
Both devices use an SPI-compatible serial interface for configuration and data readout. The interface supports daisy-chaining and is compatible with standard SPI modes, allowing connection to most microcontrollers and DSPs.
Both the ADS1246IPW and ADS1256IDBT operate from an analog supply (AVDD) of 5 V (range 4.75 V to 5.25 V) and a digital supply (DVDD) of 2.7 V to 5.25 V. Both also require an external reference voltage for accurate conversion.
The ADS1256IDBT is better suited for multi-sensor systems because its integrated 8-channel multiplexer (4 differential) allows multiple inputs to be scanned by a single ADC. The ADS1246IPW, with only one differential input, is better suited to single-channel or low-channel-count designs where board space is critical.