ADS1282HIPWR
德州儀器
- Lifecycle
- Active
- Stock
- 5203 件
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1282HIPWR 和 ADS1241E 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1241E and ADS1282HIPWR are not drop-in replacements for one another. The ADS1241E is a 24-bit, 8-channel delta-sigma ADC in a 28-pin SSOP with a single unipolar/bipolar supply and SPI interface, while the ADS1282HIPWR is a 31-bit, 2-channel delta-sigma ADC in a 28-pin TSSOP with integrated PGA and a different supply and interface architecture. Designers must validate channel count, resolution, package footprint, and supply/interface compatibility before considering substitution.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1241E | ADS1282HIPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 31 | Higher resolution enables finer measurement of small signal changes, which is critical for precision sensing applications. |
| Number of input channels | 8 (single-ended) / 4 (differential) | 2 (differential) | Channel count determines how many sensors or signal sources can be connected without external multiplexing. |
| Maximum sample rate | 15 SPS | 4000 SPS | Sample rate limits the bandwidth of signals that can be captured; higher rates suit faster-changing or seismic/vibration signals. |
| Interface type | SPI | SPI | Both use SPI, so the host microcontroller interface is compatible, but timing and register maps differ. |
| Supply voltage (analog) | 2.7 V to 5.25 V | 4.75 V to 5.25 V (analog) / 2.7 V to 3.6 V (digital) | Supply range affects compatibility with the system power rail and low-voltage operation capability. |
| PGA / gain stage | Yes (on-chip PGA) | Yes (on-chip PGA) | An integrated PGA allows direct amplification of low-level sensor signals, reducing external components. |
| Package | SSOP-28 | TSSOP-28 | Package footprint and pinout affect PCB layout and whether a drop-in replacement is possible. |
| Operating temperature range | -40 °C to +85 °C | -40 °C to +85 °C | Temperature range determines suitability for industrial and harsh-environment applications. |
| Input type | Single-ended / differential | Differential | Differential inputs improve noise rejection; single-ended support offers flexibility for simpler sensor connections. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1282HIPWR | ADS1241E |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 31 | 24 |
| Sampling Rate (Per Second) | 4k | - |
| Number of Inputs | 2 | 8 |
| Input Type | Differential | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | ADC | MUX-PGA-ADC |
| Number of A / D Converters | 1 | - |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 5V | 2.7V ~ 3.3V, 5V |
| Voltage - Supply, Digital | 1.65V ~ 3.6V | 2.7V ~ 5.25V |
| Features | PGA | PGA |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | - |
| Base Product Number | ADS1282 | - |
| Sampling Rate(Per Second) | - | 15 |
| Number of A/D Converters | - | 1 |
The ADS1241E is a 24-bit delta-sigma ADC with a maximum data rate of 15 SPS and a single-channel differential input, housed in a 28-pin TSSOP package. The ADS1282HIPWR is a 31-bit delta-sigma ADC with data rates up to 4 kSPS, featuring a dual-channel input multiplexer and integrated PGA, supplied in a 28-pin TSSOP package. The ADS1282HIPWR targets high-resolution seismic and energy exploration applications, while the ADS1241E targets low-speed precision measurement such as temperature and pressure sensing.
No. Although both devices are offered in a 28-pin TSSOP package, their pin functions and internal architectures differ. The ADS1241E provides a single differential input with external reference and SPI-compatible serial interface, whereas the ADS1282HIPWR integrates a dual-input multiplexer, PGA, and additional control pins. A direct PCB drop-in replacement is not supported; the design must be revalidated against the respective datasheets.
The ADS1241E provides 24-bit resolution with a programmable data rate up to 15 SPS. The ADS1282HIPWR provides 31-bit resolution with selectable data rates up to 4 kSPS. The ADS1282HIPWR therefore offers significantly higher throughput and resolution, making it suitable for dynamic high-resolution signal acquisition, while the ADS1241E is intended for slow, high-precision DC measurements.
The ADS1241E has a single differential input channel with a fixed-gain input buffer. The ADS1282HIPWR includes a two-channel differential input multiplexer and an integrated programmable gain amplifier (PGA) with selectable gains, allowing it to interface with a wider range of sensor signal amplitudes without external conditioning circuitry.
The ADS1241E operates from a single 2.7 V to 5.25 V analog supply and a 2.7 V to 5.25 V digital supply, with typical power consumption in the low milliwatt range at low data rates. The ADS1282HIPWR operates from a 5 V analog supply and a 3.3 V digital supply, with power consumption dependent on the selected data rate and PGA settings. Designers should consult the respective datasheets for exact quiescent current and power-down specifications.
The ADS1241E is suited for low-speed, high-precision DC measurements such as temperature, pressure, and weigh-scale sensing where data rates below 15 SPS are sufficient. The ADS1282HIPWR is designed for high-resolution dynamic signal acquisition, including seismic data recorders, geophysical instrumentation, and energy exploration systems that require up to 4 kSPS throughput with 31-bit resolution.
Yes. Both the ADS1241E and ADS1282HIPWR provide SPI-compatible serial interfaces for configuration and data readout. However, the register maps, command sets, and timing requirements differ between the two devices, so firmware and host interface logic must be rewritten or adapted when migrating between them.
No. The two devices differ in resolution (24-bit vs 31-bit), maximum data rate (15 SPS vs 4 kSPS), input multiplexing, PGA integration, pin functions, and register architecture. A direct replacement is not possible without redesigning the analog front end, updating firmware, and revalidating the PCB layout against the target device datasheet.