ADS1240E
德州儀器
- Lifecycle
- Active
- Stock
- 5619 件
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS1240E 和 ADS1253EG4 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS1240E and ADS1253EG4 are both 24-bit delta-sigma ADCs, but they differ in resolution architecture, input channel configuration, package footprint, and interface timing, so the ADS1253EG4 cannot be used as a direct drop-in substitute for the ADS1240E without redesign and validation.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1240E | ADS1253EG4 | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma ADCs, so resolution is equivalent for high-precision measurement applications. |
| Number of input channels | 4 (differential) | 1 (differential) | The ADS1240E supports multiple differential inputs, while the ADS1253EG4 is single-channel; this affects how many signals can be measured without external multiplexing. |
| Maximum data rate (SPS) | 15 | 20000 | The ADS1253EG4 offers a much higher sampling rate, making it suitable for faster dynamic signals, whereas the ADS1240E targets slow, high-accuracy measurements. |
| Interface type | SPI (serial) | SPI (serial) | Both use a serial SPI interface, simplifying digital connection to microcontrollers and DSPs. |
| Supply voltage (analog) | 2.7 V to 5.25 V | 4.75 V to 5.25 V | The ADS1240E operates over a wider low-voltage range, while the ADS1253EG4 requires a nominal 5 V supply, affecting system power design. |
| PGA / gain stage | Yes (on-chip PGA) | No (fixed gain) | An on-chip PGA in the ADS1240E allows direct amplification of small sensor signals, whereas the ADS1253EG4 requires external signal conditioning. |
| Package type | SSOP-20 | SSOP-16 | Different package pin counts and footprints affect PCB layout and drop-in substitutability. |
| Operating temperature range | -40 °C to +85 °C | -40 °C to +85 °C | Both cover the industrial temperature range, so environmental suitability is equivalent. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1240E | ADS1253EG4 |
|---|---|---|
| Supplier | - | Rochester Electronics, LLC,Texas Instruments |
| Part Status | Active | Discontinued at Digi-Key |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | - | 20k |
| Number of Inputs | 4 | 4 |
| Input Type | Differential, Single Ended | Differential |
| Data Interface | SPI | SPI |
| Configuration | MUX-PGA-ADC | MUX-ADC |
| Number of A/D Converters | - | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 2.7V ~ 3.3V, 5V | 5V |
| Voltage - Supply, Digital | 2.7V ~ 5.25V | 5V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Base Product Number | ADS1240 | - |
| Sampling Rate (Per Second) | 15 | - |
| Number of A / D Converters | 1 | - |
| Features | PGA | - |
| Mounting Type | Surface Mount | - |
| Packaging | Tube | - |
The ADS1240E is a 24-bit delta-sigma ADC with a programmable gain amplifier (PGA) and a maximum data rate of 15 SPS, housed in a 24-pin TSSOP package. The ADS1253EG4 is a 24-bit delta-sigma ADC without an integrated PGA, offering a higher maximum data rate of 20.8 kSPS, and is supplied in a 16-pin SSOP package. The ADS1240E targets low-speed, high-resolution sensor applications, while the ADS1253EG4 suits higher-speed data acquisition.
No. The ADS1240E uses a 24-pin TSSOP package, while the ADS1253EG4 uses a 16-pin SSOP package. The pin counts, pin functions, and package footprints differ, so they are not direct drop-in replacements and require separate PCB layouts.
No. The ADS1240E integrates a PGA that supports gains from 1 to 128, allowing direct connection of low-level sensor signals. The ADS1253EG4 does not include an on-chip PGA; external signal conditioning or amplification is required for low-level inputs.
The ADS1240E supports data rates up to 15 SPS, optimized for high-resolution, low-speed measurements. The ADS1253EG4 supports data rates up to 20.8 kSPS, making it suitable for faster acquisition requirements. The trade-off is that higher output rates generally reduce effective resolution and noise performance.
Both devices operate from a single 5 V analog supply (AVDD) and a 2.7 V to 5.25 V digital supply (DVDD), per their respective manufacturer datasheets. Designers should verify the exact recommended operating conditions in the official Texas Instruments datasheets before finalizing power supply designs.
The ADS1240E is generally better suited for low-level sensor measurements because its integrated PGA (gains up to 128) allows small sensor signals to be amplified before conversion, improving effective resolution. The ADS1253EG4 lacks an internal PGA, so low-level signals would require external amplification.
No. The two devices differ in package, pinout, register set, and command structure. The ADS1240E and ADS1253EG4 have different SPI command interfaces and configuration registers, so firmware and PCB layout changes are required. A direct substitution without redesign is not supported.
The ADS1240E is offered in a 24-pin TSSOP package, and the ADS1253EG4 in a 16-pin SSOP package. Both are specified for the industrial temperature range of -40°C to +85°C according to their Texas Instruments datasheets. Designers should confirm the exact package suffix and temperature grade against the ordering information in the official datasheets.