ADS114S08IPBS
德州儀器
- Lifecycle
- Active
- Stock
- 4543 件
- Package
- TQFP-32
- Series
- 資料獲取-模數轉換器(ADC)
對 ADS114S08IPBS 和 ADS1196CPAG 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADS114S08IPBS and ADS1196CPAG are not drop-in replacements for one another. The ADS114S08IPBS is a 16-bit, 8-channel precision delta-sigma ADC with an SPI interface in a TQFP-32 package, while the ADS1196CPAG is a 16-bit, 6-channel biopotential front-end with integrated ECG/EEG features in a TQFP-64 package. Their channel counts, package footprints, and target applications differ substantially, so a direct board-level substitution is not feasible without redesign.
德州儀器
德州儀器
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS114S08IPBS | ADS1196CPAG | Why it matters |
|---|---|---|---|
| Resolution (bits) | 16 | 16 | Both are 16-bit delta-sigma ADCs, so nominal resolution is equivalent for substitutability. |
| Number of input channels | 8 (single-ended) / 4 (differential) | 6 (single-ended) / 3 (differential) | Channel count determines how many signals can be measured; the ADS114S08 offers more inputs than the ADS1196. |
| Maximum sample rate (SPS) | 2000 | 8000 | Sample rate affects the bandwidth of signals that can be captured; the ADS1196 supports faster sampling. |
| Interface type | SPI | SPI | Both use SPI, so the host microcontroller interface is compatible between the two parts. |
| Supply voltage (analog) | 2.7 V to 5.25 V (AVDD) | 2.7 V to 5.25 V (AVDD) | Analog supply range must match the system rail; both parts support the same AVDD range. |
| Integrated PGA | Yes (1 to 128 gain) | Yes (1 to 12 gain) | A PGA allows direct connection of small signals; the ADS114S08 offers higher maximum gain. |
| Package | TQFP-32 | TQFP-64 | Package footprint and pin count affect PCB layout and drop-in compatibility; these differ significantly. |
| Operating temperature range | -40 °C to +125 °C | -40 °C to +85 °C | Temperature range determines suitability for harsh environments; the ADS114S08 supports a wider range. |
| Integrated features | Internal reference, oscillator, temperature sensor, burnout detection | Internal reference, oscillator, respiration measurement, lead-off detection | On-chip features reduce external component count; the ADS1196 targets ECG/biopotential applications while the ADS114S08 targets general precision sensing. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS114S08IPBS | ADS1196CPAG |
|---|---|---|
| Supplier | - | Rochester Electronics, LLC,Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | 16 | 16 |
| Number of Channels | - | 6 |
| Power (Watts) | - | 6.9 mW |
| Voltage - Supply, Analog | 2.7V ~ 5.25V | 2.7V ~ 5.25V |
| Voltage - Supply, Digital | 2.7V ~ 3.6V | 1.65V ~ 3.6V |
| Mounting Type | - | Surface Mount |
| Sampling Rate(Per Second) | 4k | - |
| Number of Inputs | 12 | - |
| Input Type | Differential, Pseudo-Differential, Single Ended | - |
| Data Interface | SPI | - |
| Configuration | MUX-PGA-ADC | - |
| Number of A/D Converters | 1 | - |
| Architecture | Sigma-Delta | - |
| Reference Type | External, Internal | - |
| Features | PGA, Temperature Sensor | - |
| Operating Temperature | -50°C ~ 125°C | - |
The ADS114S08IPBS is a 16-bit, 8-channel delta-sigma ADC designed for precision sensor measurement, featuring a programmable gain amplifier (PGA), internal oscillator, and SPI interface in a TQFP-32 package. The ADS1196CPAG is a 24-bit, 6-channel simultaneously sampling delta-sigma ADC with an integrated ECG front-end, respiration impedance measurement, and SPI interface in a TQFP-64 package. The ADS114S08IPBS targets general-purpose precision sensing, while the ADS1196CPAG targets biopotential and ECG applications.
No. The ADS114S08IPBS is supplied in a 32-pin TQFP (PBS) package, while the ADS1196CPAG is supplied in a 64-pin TQFP (PAG) package. The different pin counts and pin functions prevent direct PCB footprint compatibility, so these devices are not drop-in replacements for each other.
The ADS114S08IPBS provides 16-bit resolution with programmable data rates up to 2 kSPS. The ADS1196CPAG provides 24-bit resolution with programmable data rates up to 8 kSPS per channel. The ADS1196CPAG offers higher resolution and higher maximum throughput, while the ADS114S08IPBS offers 16-bit precision at lower data rates for general sensor applications.
Yes. The ADS114S08IPBS includes an integrated low-noise PGA with selectable gains from 1 to 128. The ADS1196CPAG includes an integrated PGA with selectable gains of 1, 2, 3, 4, 6, 8, and 12. Both devices allow direct connection of low-level sensor signals without external amplification, though the available gain settings differ.
The ADS114S08IPBS operates from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 2.7 V to 3.6 V. The ADS1196CPAG operates from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 1.7 V to 3.6 V. Both devices support unipolar and bipolar analog supplies within their specified ranges.
The ADS1196CPAG is specifically designed for ECG and biopotential applications, integrating a 6-channel simultaneously sampling 24-bit ADC, a respiration impedance measurement channel, lead-off detection, and a Wilson Central Terminal (WCT) buffer. The ADS114S08IPBS is a general-purpose precision ADC without these dedicated biopotential features, making the ADS1196CPAG the appropriate choice for ECG front-end designs.
The ADS114S08IPBS provides 8 single-ended or 4 differential input channels with a flexible input multiplexer. The ADS1196CPAG provides 6 differential input channels that are sampled simultaneously, which is essential for multi-lead ECG acquisition where phase alignment between channels matters. The ADS114S08IPBS uses a multiplexed architecture, so channels are sampled sequentially rather than simultaneously.
Both devices use a serial peripheral interface (SPI) for communication with a host microcontroller. The ADS114S08IPBS supports SPI with a dedicated data-ready (DRDY) output. The ADS1196CPAG also supports SPI and includes a DRDY output along with additional control and status signals for its ECG-specific functions. Both are compatible with standard SPI hosts, but register maps and command sets differ between the two devices.