- PMIC-電壓參攷
對 ADR435BRZ 和 ADR433AR 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The ADR433AR is a viable functional substitute for the ADR435BRZ in applications where a 3.0 V reference is acceptable and the tighter initial accuracy and lower output noise of the ADR435BRZ are not mandatory. Both devices share the same series voltage reference topology, SOIC-8 footprint, and industrial temperature range, but designers must validate the 2.5 V to 3.0 V output shift, the relaxed initial accuracy tolerance, and the higher dropout headroom before committing to the substitution.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADR435BRZ | ADR433AR | Why it matters |
|---|---|---|---|
| Output Voltage | 5.0 V | 3.0 V | The nominal reference voltage determines the full-scale input range of the ADC or DAC the reference drives; a 5.0 V and 3.0 V reference are not directly interchangeable in a given circuit. |
| Initial Accuracy | ±0.04% (B grade) | ±0.13% (A grade) | Initial accuracy sets the absolute error of the reference at room temperature; the tighter B-grade tolerance of the ADR435BRZ yields lower system calibration error. |
| Temperature Coefficient | 3 ppm/°C (B grade) | 10 ppm/°C (A grade) | Drift over temperature directly affects accuracy across the operating range; the lower tempco of the ADR435BRZ provides more stable performance in precision applications. |
| Output Current Capability | 30 mA (source), 20 mA (sink) | 30 mA (source), 20 mA (sink) | Drive capability determines how many loads or how much load current the reference can support while maintaining regulation. |
| Supply Voltage Range | 7.0 V to 18 V | 5.0 V to 18 V | The minimum supply headroom differs because the output voltages differ; the ADR433AR can operate from a lower supply, which matters for low-voltage systems. |
| Output Voltage Noise (0.1 Hz to 10 Hz) | 8 µV p-p (typical) | 3.4 µV p-p (typical) | Low-frequency noise limits achievable resolution in high-resolution converters; the lower absolute noise of the ADR433AR benefits precision low-frequency measurements. |
| Long-Term Drift | 25 ppm/1000 hr (typical) | 25 ppm/1000 hr (typical) | Long-term stability affects recalibration intervals and lifetime accuracy of the system. |
| Package | 8-lead SOIC | 8-lead SOIC | Package and pinout compatibility determine whether the parts are drop-in replacements on an existing PCB. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADR435BRZ | ADR433AR |
|---|---|---|
| Series | XFET® | XFET® |
| Part Status | Active | Obsolete |
| Mounting Type | Surface Mount | Surface Mount |
| Reference Type | Series | - |
| Output Type | Fixed | - |
| Voltage - Output (Min/Fixed) | 5V | - |
| Current - Output | 30 mA | - |
| Tolerance | ±0.04% | - |
| Temperature Coefficient | 3ppm/°C | - |
| Noise - 01 Hzto10 Hz | 8µVp-p | - |
| Voltage - Input | 7V ~ 18V | - |
| Supply Current | 800µA | - |
| Operating Temperature | -40°C ~ 125°C (TA) | - |
The ADR435BRZ is a 5.0 V precision voltage reference with an initial accuracy of ±0.04% (B grade) and a maximum temperature coefficient of 3 ppm/°C, housed in an 8-lead SOIC package. The ADR433AR is a 3.0 V precision voltage reference with an initial accuracy of ±0.13% (A grade) and a maximum temperature coefficient of 10 ppm/°C, also in an 8-lead SOIC package. The primary differences are output voltage (5.0 V vs 3.0 V), accuracy grade, and temperature coefficient.
No, they cannot be used interchangeably without design changes. The ADR435BRZ provides a 5.0 V output while the ADR433AR provides a 3.0 V output, so the output voltage differs by 2.0 V. Any circuit designed for one output voltage must be re-evaluated for compliance with the other reference voltage, including ADC/DAC full-scale ranges and downstream regulation.
The ADR435BRZ (B grade) offers an initial accuracy of ±0.04% maximum at 25°C. The ADR433AR (A grade) offers an initial accuracy of ±0.13% maximum at 25°C. The B-grade ADR435BRZ therefore provides tighter initial output tolerance than the A-grade ADR433AR.
The ADR435BRZ specifies a maximum temperature coefficient of 3 ppm/°C over the −40°C to +125°C temperature range. The ADR433AR specifies a maximum temperature coefficient of 10 ppm/°C over the same range. The ADR435BRZ therefore offers superior temperature stability for precision applications.
Yes, both devices are offered in an 8-lead SOIC package (R-8 suffix) with the same pin configuration, including the VOUT, VIN, GND, TRIM, and noise-reduction/sense pins as defined in the respective Analog Devices datasheets. This allows PCB footprint compatibility, though the output voltage difference still prevents direct electrical substitution.
The ADR435BRZ specifies low output voltage noise of approximately 8 µV p-p (0.1 Hz to 10 Hz) typical. The ADR433AR specifies output voltage noise of approximately 3.5 µV p-p (0.1 Hz to 10 Hz) typical. Both are low-noise references suitable for precision data conversion, with the ADR433AR having lower absolute noise at its 3.0 V output.
The ADR435BRZ requires a supply voltage of at least 5.3 V (VOUT + 0.3 V dropout) and operates up to 18 V. The ADR433AR requires a supply voltage of at least 3.3 V and operates up to 18 V. The lower output voltage of the ADR433AR allows operation from lower supply rails, which can reduce power dissipation in 3.3 V systems.
The ADR435BRZ (5.0 V, 3 ppm/°C, ±0.04%) is typically selected for high-precision 5 V systems such as 16-bit and higher ADCs/DACs, precision instrumentation, and industrial measurement where tight initial accuracy and low drift are critical. The ADR433AR (3.0 V, 10 ppm/°C, ±0.13%) is typically used in 3.0 V or 3.3 V portable and battery-powered systems, low-power data acquisition, and applications where a 3.0 V reference is required and moderate precision is sufficient.