ADF4360-1BCPZ vs ADF4360-2BCP

對 ADF4360-1BCPZ 和 ADF4360-2BCP 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADF4360-1BCPZ and ADF4360-2BCP are both integrated integer-N PLL synthesizers with VCO from the same ADF4360 family, sharing an identical 24-lead LFCSP footprint and 3.0 V to 3.6 V supply range, so they are functionally interchangeable at the board level. The primary distinction is the on-chip VCO frequency band, which determines the usable output range and requires the loop filter and divider settings to be recalculated for the target frequency plan. Designers should confirm that the required output frequency falls within the selected variant's VCO range before substituting.

Package Type High match
Supply Voltage Range High match
VCO Frequency Range Validation required
Output Frequency Range Validation required

Parts at a glance

Part A

ADF4360-1BCPZ

ADI公司

Lifecycle
Active
Stock
1269 件
Package
WFQFN-24
Series
時鐘定時-時鐘發生器、PLL、頻率合成器
Part B

ADF4360-2BCP

ADI公司

Lifecycle
Active
Stock
4277 件
Package
WFQFN-24
Series
時鐘定時-時鐘發生器、PLL、頻率合成器

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADF4360-1BCPZ ADF4360-2BCP Why it matters
Frequency Range (Min) 1050 MHz 1850 MHz Defines the lowest output frequency the synthesizer can generate; a lower minimum allows operation in lower bands.
Frequency Range (Max) 2400 MHz 2170 MHz Sets the highest achievable output frequency; determines suitability for higher-band applications.
VCO Frequency Range 1050 MHz to 2400 MHz 1850 MHz to 2170 MHz The integrated VCO tuning range directly constrains which output frequencies can be locked without external components.
Supply Voltage 3.0 V to 3.6 V 3.0 V to 3.6 V Both parts share the same supply requirement, so power-rail design is interchangeable.
Package / Pin Count 24-Lead LFCSP 24-Lead LFCSP Identical footprint and pinout enable drop-in board replacement without layout changes.
Output Type Differential (complementary) outputs Differential (complementary) outputs Matching output topology ensures the same external matching and buffer circuitry can be reused.
Programmable Divider / Interface SPI-compatible 3-wire interface SPI-compatible 3-wire interface Same digital control interface means firmware and microcontroller connections remain compatible.
Typical Application Band ~1.0 GHz to 2.4 GHz (e.g., WLAN, ISM) ~1.85 GHz to 2.17 GHz (e.g., PCS, DCS) The intended operating bands differ, so substitution depends on whether the target frequency falls within the narrower ADF4360-2 range.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADF4360-1BCPZ ADF4360-2BCP
Supplier - Rochester Electronics, LLC
Part Status Active Obsolete
Type Fanout Distribution, Integer N Synthesizer (RF) Fanout Distribution, Integer N Synthesizer (RF)
PLL Yes Yes
Input CMOS, TTL CMOS
Output Clock Clock
Ratio - Input: Output 1:2 1:2
Differential - Input: Output No/No No/No
Frequency - Max 2.45GHz 2.17GHz
Divider / Multiplier Yes/No Yes/No
Voltage - Supply 3V ~ 3.6V 3V ~ 3.6V
Mounting Type Surface Mount Surface Mount
Number of Circuits 1 -
Operating Temperature -40°C ~ 85°C -

Frequently asked questions

What are the key differences between the ADF4360-1BCPZ and the ADF4360-2BCP?

Both are integrated integer-N synthesizers with VCOs from Analog Devices, but they differ in frequency range and package. The ADF4360-1BCPZ covers 2050 MHz to 2450 MHz and is supplied in a 24-lead LFCSP (CP-24-2). The ADF4360-2BCP covers 1850 MHz to 2170 MHz and is supplied in a 24-lead LFCSP (CP-24). The ADF4360-1BCPZ is the RoHS-compliant version of the ADF4360-1, while the ADF4360-2BCP is the non-RoHS lead-frame variant of the ADF4360-2.

Can the ADF4360-1BCPZ and ADF4360-2BCP be used interchangeably in the same design?

Not directly. Although both share the same 24-lead LFCSP footprint and register map, their VCO frequency ranges differ: 2050–2450 MHz for the ADF4360-1BCPZ versus 1850–2170 MHz for the ADF4360-2BCP. A design tuned for one frequency band will not cover the other without revalidating the loop filter, VCO tuning range, and output matching network against the respective datasheet.

What is the difference in RoHS compliance between the ADF4360-1BCPZ and the ADF4360-2BCP?

The ADF4360-1BCPZ is the RoHS-compliant ordering code, indicated by the "Z" suffix in the part number. The ADF4360-2BCP does not carry the "Z" suffix and is the non-RoHS version. Designs requiring RoHS compliance should use the "Z"-suffixed variant of the corresponding frequency option.

Do the ADF4360-1BCPZ and ADF4360-2BCP share the same package and pinout?

Both devices are offered in a 24-lead LFCSP package with the same pin functions and register interface, so the PCB land pattern is compatible. However, the exact package code differs (CP-24-2 for the ADF4360-1BCPZ versus CP-24 for the ADF4360-2BCP), and the designer should confirm the package drawing in the respective datasheet before layout.

What supply voltage and current consumption do the ADF4360-1BCPZ and ADF4360-2BCP require?

Both devices operate from a 3.0 V to 3.6 V supply. Typical current consumption is approximately 45 mA for the ADF4360-1BCPZ and approximately 45 mA for the ADF4360-2BCP, with a power-down mode that reduces current to a few microamperes. Exact values should be taken from the respective Analog Devices datasheets.

What is the phase noise performance of the ADF4360-1BCPZ and ADF4360-2BCP?

Both parts specify a normalized phase noise floor of approximately -219 dBc/Hz in the datasheet, with typical in-band phase noise around -88 dBc/Hz at a 1 kHz offset for a 200 kHz PFD frequency. Actual phase noise depends on the selected VCO band, loop filter, and reference, so the designer should consult the phase noise plots in the respective datasheet.

What is the difference in output frequency range between the ADF4360-1BCPZ and the ADF4360-2BCP?

The ADF4360-1BCPZ VCO operates from 2050 MHz to 2450 MHz, while the ADF4360-2BCP VCO operates from 1850 MHz to 2170 MHz. Both provide a divided output and a complementary output, and the choice between them should be based on the target RF band of the application.

Are the ADF4360-1BCPZ and ADF4360-2BCP programmable through the same serial interface?

Yes. Both devices use the same 3-wire serial interface (CLK, DATA, LE) and the same 24-bit register map, so firmware written for one can generally be reused for the other. The register settings for the VCO band and charge pump current should still be adjusted to match the frequency range of the selected part.