ADF4156BCPZ vs ADF4112BCP

對 ADF4156BCPZ 和 ADF4112BCP 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADF4156BCPZ and ADF4112BCP are both fractional-N PLL frequency synthesizers, but they differ in maximum operating frequency, package footprint, and supply voltage range, so the ADF4112BCP cannot be used as a direct drop-in substitute for the ADF4156BCPZ without design validation.

Different maximum frequency Different package footprint Different supply voltage range Different phase noise profile

Parts at a glance

Part A

ADF4156BCPZ

ADI公司

Lifecycle
Active
Stock
1350 件
Package
WFQFN-20
Series
時鐘定時-時鐘發生器、PLL、頻率合成器
Part B

ADF4112BCP

ADI公司

Lifecycle
Active
Stock
6937 件
Package
WFQFN-20
Series
時鐘定時-時鐘發生器、PLL、頻率合成器

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADF4156BCPZ ADF4112BCP Why it matters
Maximum Operating Frequency 6 GHz 3 GHz Determines the highest RF input frequency the PLL synthesizer can handle; the ADF4156 supports higher-frequency applications.
Number of Fractional/Integer Modes Fractional-N Integer-N Fractional-N allows finer frequency resolution and lower phase noise for a given reference, while integer-N is simpler and often lower cost.
RF Input Frequency Range 0.5 GHz to 6 GHz 0.2 GHz to 3 GHz Defines the usable band of the synthesizer; the two parts cover different application frequency bands.
Supply Voltage Range 2.7 V to 3.3 V 2.7 V to 3.3 V Both operate from the same supply range, so power-rail compatibility is maintained.
Package Type 20-Lead LFCSP 16-Lead LFCSP Different package footprints and pin counts affect PCB layout and drop-in substitutability.
Operating Temperature Range -40°C to +85°C -40°C to +85°C Both support industrial temperature ranges, so environmental compatibility is equivalent.
Programmable Charge Pump Current Up to 5 mA Up to 5 mA Charge pump current affects loop filter design and lock time; matching values simplify loop redesign.
Reference Input Frequency Up to 250 MHz Up to 250 MHz Determines the maximum reference clock the phase detector can accept; identical limits ease substitution.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADF4156BCPZ ADF4112BCP
Supplier - Rochester Electronics, LLC
Part Status Active Obsolete
Type Fractional N Synthesizer (RF) Clock/Frequency Synthesizer (RF)
PLL Yes Yes
Input CMOS, TTL Clock
Output Clock Clock
Ratio - Input: Output 2:1 2:1
Differential - Input: Output Yes/No Yes/No
Frequency - Max 6.2GHz 3GHz
Divider / Multiplier Yes/Yes Yes/No
Voltage - Supply 2.7V ~ 3.3V 2.7V ~ 5.5V
Mounting Type Surface Mount Surface Mount
Number of Circuits 1 -
Operating Temperature -40°C ~ 85°C -

Frequently asked questions

What are the key differences between the ADF4156BCPZ and the ADF4112BCP?

The ADF4156BCPZ is a fractional-N PLL frequency synthesizer with an integrated VCO, operating up to 6 GHz, while the ADF4112BCP is an integer-N PLL synthesizer without an integrated VCO, operating up to 3 GHz. The ADF4156BCPZ supports fractional-N operation for finer frequency resolution, whereas the ADF4112BCP uses integer-N architecture.

Are the ADF4156BCPZ and ADF4112BCP pin-compatible?

No. The ADF4156BCPZ is supplied in a 20-lead LFCSP package, while the ADF4112BCP is supplied in a 16-lead TSSOP package. The different package types and pin counts mean they are not pin-compatible and cannot be directly interchanged on the same PCB footprint.

What is the maximum operating frequency of each device?

The ADF4156BCPZ supports RF input frequencies up to 6 GHz. The ADF4112BCP supports RF input frequencies up to 3 GHz. The higher frequency capability of the ADF4156BCPZ makes it suitable for higher-band applications.

Do both devices require an external VCO?

No. The ADF4156BCPZ includes an integrated VCO, reducing external component count and board space. The ADF4112BCP does not include an integrated VCO and requires an external VCO to complete the PLL loop.

What are the supply voltage requirements for the ADF4156BCPZ and ADF4112BCP?

Both devices operate from a nominal 3.0 V to 3.6 V supply. Designers should consult the respective manufacturer datasheets for detailed supply voltage ranges and decoupling requirements.

Which device offers finer frequency resolution?

The ADF4156BCPZ offers finer frequency resolution because it uses fractional-N architecture, allowing step sizes smaller than the phase detector frequency. The ADF4112BCP, being integer-N, has frequency resolution limited to the phase detector comparison frequency.

Can the ADF4112BCP be used as a drop-in replacement for the ADF4156BCPZ?

No. The devices differ in package type, pin count, PLL architecture (integer-N vs. fractional-N), integrated VCO presence, and maximum operating frequency. A direct drop-in replacement is not possible without redesigning the PCB and validating the PLL loop and frequency plan.