AD822BRZ vs AD8221AR

對 AD822BRZ 和 AD8221AR 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The AD822BRZ and AD8221AR are not drop-in replacements for one another. Although both are precision instrumentation amplifiers in SOIC-8 packages, they differ in gain programming architecture, bandwidth, supply range, and input bias current, so the AD8221AR cannot be substituted directly for the AD822BRZ without circuit redesign and revalidation.

Different gain programming Different bandwidth Different supply range Different input bias current

Parts at a glance

Part A

AD822BRZ

ADI公司

Lifecycle
Active
Stock
2821 件
Package
SOIC-8
Series
線性放大器-儀器、運算放大器、緩衝放大器
Part B

AD8221AR

ADI公司

Lifecycle
Active
Stock
5847 件
Series
Linear - Amplifiers - Instrumentation, Op Amps, Buffer Amps

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD822BRZ AD8221AR Why it matters
Amplifier Type Dual-channel general-purpose instrumentation amplifier Single-channel precision instrumentation amplifier Channel count and architecture determine whether the part can drop into a given circuit; a dual general-purpose amp is not a direct substitute for a single precision amp.
Number of Channels 2 1 The number of independent amplifier channels must match the signal paths in the design; a mismatch changes board layout and channel count.
Gain Setting Method External resistor (single resistor sets gain) External resistor (single resistor sets gain) Both use a single external gain resistor, but the gain equation and resistor value differ, so the same resistor will not yield the same gain.
Input Offset Voltage (max) ~800 µV (B grade) ~60 µV (A grade) Offset voltage directly limits DC accuracy; the precision AD8221AR offers far lower offset, which matters for low-level signal measurement.
Gain Bandwidth / -3 dB Bandwidth ~1.8 MHz (G = 1) ~825 kHz (G = 1) Bandwidth determines the maximum signal frequency the amplifier can handle at a given gain; the two parts differ significantly.
CMRR (min, G = 100) ~80 dB ~110 dB Common-mode rejection ratio governs how well the amplifier rejects interference; the precision part provides much higher CMRR for noisy environments.
Supply Voltage Range ±2.3 V to ±18 V (dual supply) ±2.3 V to ±18 V (dual supply) Both support similar supply rails, so power-supply compatibility is generally maintained between the two parts.
Input Bias Current (max) ~25 nA ~1.5 nA Bias current affects error in high-impedance sources; the lower bias current of the precision part reduces offset errors in sensor interfaces.
Package 8-lead SOIC 8-lead SOIC Package compatibility affects PCB footprint; both share the same SOIC-8 outline, easing physical substitution.
Operating Temperature Range -40 °C to +85 °C -40 °C to +85 °C Matching temperature ranges ensure both parts meet the same environmental requirements in the target application.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD822BRZ AD8221AR
Part Status Active Obsolete
Amplifier Type General Purpose Instrumentation
Number of Circuits 2 1
Slew Rate 3V/µs 2V/µs
Current - Input Bias 2 pA 500 pA
Voltage - Input Offset 300 µV 60 µV
Supply Current 1.24mA 900µA
Current - Output / Channel 20 mA 18 mA
Voltage - Supply Span (Min) - 4.6 V
Voltage - Supply Span (Max) - 36 V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Base Product Number - AD8221
-3 dB Bandwidth 1.9 MHz 825 kHz
Output Type Rail-to-Rail -
Gain Bandwidth Product 1.9 MHz -
Voltage - Supply Span(Min) 5 V -
Voltage - Supply Span(Max) 30 V -

Frequently asked questions

What are the fundamental differences between the AD822BRZ and the AD8221AR?

The AD822BRZ is a dual, low-power, precision operational amplifier from Analog Devices, while the AD8221AR is a single, high-performance instrumentation amplifier. The AD822BRZ is a general-purpose op-amp intended for signal conditioning and filtering, whereas the AD8221AR is a dedicated in-amp designed for accurate differential signal amplification with a single external resistor setting the gain.

Are the AD822BRZ and AD8221AR pin-compatible or interchangeable?

No. The AD822BRZ is supplied in an 8-lead SOIC package with a standard dual op-amp pinout (two amplifiers sharing power pins), while the AD8221AR is supplied in an 8-lead SOIC package with an instrumentation amplifier pinout (including gain-setting resistor pins and a reference pin). The pin functions and internal topology differ, so they are not direct substitutes.

How do the input offset voltage specifications compare between the AD822BRZ and AD8221AR?

The AD822BRZ (B grade) specifies a maximum input offset voltage of 100 µV at 25°C. The AD8221AR (A grade) specifies a maximum input offset voltage of 60 µV at 25°C. Both are precision-grade parts, but the AD8221AR offers a tighter offset limit, which is typical for instrumentation amplifier specifications.

What is the gain configuration for each device?

The AD822BRZ is a fixed-gain operational amplifier; closed-loop gain is set externally by feedback resistors in the user's circuit. The AD8221AR is a programmable-gain instrumentation amplifier whose gain is set by a single external resistor (R_G) according to the manufacturer's gain equation, allowing gains from 1 to 1000 without external op-amp feedback networks.

How do the supply voltage and quiescent current ratings compare?

The AD822BRZ operates from dual supplies of ±2.5 V to ±15 V (or single-supply equivalents) and typically draws about 1.5 mA per amplifier. The AD8221AR operates from ±2.3 V to ±18 V dual supplies and typically draws about 1 mA total. Both are low-power parts, but the AD8221AR provides a wider supply range and lower total quiescent current.

Which device is better suited for bridge sensor or differential measurement applications?

The AD8221AR is specifically designed for precision differential signal acquisition, such as bridge sensors and medical instrumentation, because it provides high common-mode rejection, programmable gain, and a dedicated reference pin. The AD822BRZ can be used in differential configurations but requires an external resistor network and does not offer the same integrated CMRR performance.

Do both parts share the same operating temperature range?

Yes. Both the AD822BRZ and AD8221AR are specified for the industrial temperature range of −40°C to +85°C, making them suitable for industrial signal-conditioning environments.