AD7732BRUZ vs AD7732BRU

對 AD7732BRUZ 和 AD7732BRU 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD7732BRUZ and AD7732BRU are functionally equivalent signal-conditioning ADCs, with the BRUZ suffix denoting the RoHS-compliant package variant of the same AD7732 device. Both share identical core architecture, channel configuration, resolution, and interface, making the BRUZ a suitable functional replacement for the BRU in most designs, subject to confirming RoHS and moisture-sensitivity requirements against the original BRU specification.

Resolution and Architecture High match
Channel Count and Input Type High match
Package and Pinout High match
RoHS and Environmental Compliance Validation required

Parts at a glance

Part B

AD7732BRU

ADI公司

Lifecycle
Active
Stock
4642 件
Package
TSSOP-28
Series
資料獲取-模數轉換器(ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD7732BRUZ AD7732BRU Why it matters
Number of Channels 2 2 Determines how many analog input signals the ADC can digitize simultaneously; must match the application's channel count.
Resolution 24 bit 24 bit Sets the finest signal increment the ADC can resolve; critical for high-precision measurement applications.
Sampling Rate Up to 15.4 kSPS Up to 15.4 kSPS Defines the maximum conversion throughput; must satisfy the bandwidth requirements of the measured signal.
Input Type Differential Differential Differential inputs improve noise rejection and are required for certain sensor and bridge interfaces.
Supply Voltage 5 V (analog and digital) 5 V (analog and digital) Must be compatible with the system power rails to avoid level shifting or additional regulation.
Interface SPI / Serial SPI / Serial Determines compatibility with the host microcontroller's communication bus and firmware.
Package / Mounting 24-TSSOP (Surface Mount) 24-TSSOP (Surface Mount) Footprint and mounting style must match the PCB layout for a drop-in replacement.
RoHS Compliance RoHS Compliant (lead-free) Non-RoHS (contains lead) RoHS status affects regulatory compliance and solder process selection; the "Z" suffix denotes the lead-free variant.
Operating Temperature Range -40 °C to +105 °C -40 °C to +105 °C Must cover the ambient conditions of the target application; both variants share the same industrial range.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD7732BRUZ AD7732BRU
Supplier - Analog Devices Inc.,Rochester Electronics, LLC
Part Status Active Obsolete
Number of Bits 24 24
Sampling Rate(Per Second) 15.4k 15.4k
Number of Inputs 2 2
Input Type Differential Differential
Data Interface SPI, DSP SPI, DSP
Configuration MUX-ADC MUX-ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 2.7V ~ 3.6V, 5V 2.7V ~ 3.6V, 5V
Operating Temperature -40°C ~ 105°C -40°C ~ 105°C

Frequently asked questions

What is the difference between the AD7732BRUZ and the AD7732BRU?

The AD7732BRUZ and AD7732BRU are both 24-bit, 2-channel sigma-delta ADCs from Analog Devices in a 28-lead TSSOP package. The primary difference is the suffix: the "Z" designation in AD7732BRUZ indicates RoHS-compliant, lead-free construction, while the AD7732BRU is the non-RoHS (leaded) version. Both share the same functional specifications and are electrically equivalent.

Are the AD7732BRUZ and AD7732BRU functionally interchangeable?

Yes. Both parts are functionally identical 24-bit sigma-delta ADCs with the same pinout, package (28-lead TSSOP), and electrical specifications. The only difference is the RoHS/lead-free compliance status. They can be interchanged in designs where RoHS compliance is not a constraint, but the AD7732BRUZ is preferred for new designs requiring lead-free compliance.

What are the key specifications of the AD7732?

The AD7732 is a 24-bit, 2-channel, sigma-delta analog-to-digital converter with a programmable gain amplifier (PGA), offering a resolution of 24 bits and a maximum data rate of 15.4 kSPS. It operates from a single 5 V analog supply and a 2.7 V to 3.6 V digital supply, and is specified over the -40°C to +105°C temperature range. It is housed in a 28-lead TSSOP package.

Is the AD7732BRUZ RoHS compliant?

Yes. The "Z" suffix in AD7732BRUZ denotes RoHS compliance and lead-free construction, per Analog Devices' part numbering convention. The AD7732BRU, lacking the Z suffix, is the non-RoHS version containing lead in its termination finish.

Can the AD7732BRUZ be used as a drop-in replacement for the AD7732BRU?

Yes, in terms of form, fit, and function, the AD7732BRUZ is a drop-in replacement for the AD7732BRU because both share the same 28-lead TSSOP package, pinout, and electrical specifications. The substitution is valid provided the application does not require the leaded (non-RoHS) finish of the AD7732BRU.

What is the operating temperature range for both the AD7732BRUZ and AD7732BRU?

Both the AD7732BRUZ and AD7732BRU are specified over the industrial temperature range of -40°C to +105°C, consistent with the AD7732 datasheet specifications.

Which part should be selected for a new lead-free design?

The AD7732BRUZ should be selected for new designs requiring RoHS compliance and lead-free assembly. The AD7732BRU is the non-RoHS variant and is generally not recommended for new designs subject to RoHS or lead-free manufacturing requirements.