AD590LF
ADI公司
- Lifecycle
- Active
- Stock
- 4157 件
- Package
- CFLATPACK-2
- Series
- 溫度感測器-類比和數位輸出
對 AD590LF 和 AD590JF 的深入比較,為您帶來關於其規格和關鍵特性的寶貴見解。我們詳細介紹了重要因素,包括 RoHS 合規性、REACH 狀態、系列、安裝方式、封裝類型以及其他相關特性。並排展示差異,簡化了元件選擇,讓您更輕鬆地為您的特定應用選擇最佳方案。
Replacement verdict
The AD590JF and AD590LF are functionally interchangeable two-terminal temperature transducers sharing identical output characteristics, supply range, and calibration tolerance; the only material distinction is the specified operating temperature range, so the AD590LF is a viable replacement for the AD590JF wherever the wider military-grade temperature window is acceptable or beneficial.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD590JF | AD590LF | Why it matters |
|---|---|---|---|
| Temperature Accuracy (Calibration Error at 25°C) | ±2.5°C max | ±0.5°C max | Determines the initial absolute accuracy of the sensor; the LF grade offers a much tighter calibration tolerance, which is critical for precision temperature measurement without individual trimming. |
| Grade / Accuracy Class | J Grade | L Grade | The grade designates the guaranteed error budget; L grade is a higher-precision bin than J grade, so substitution changes the overall system accuracy specification. |
| Nonlinearity | ±0.8°C max (over full range) | ±0.3°C max (over full range) | Nonlinearity limits accuracy across the temperature span; the LF grade's tighter linearity reduces error at temperature extremes where calibration at 25°C alone cannot compensate. |
| Operating Temperature Range (Rated Performance) | -55°C to +150°C | -55°C to +150°C | Both share the same wide military-grade range, so the parts are interchangeable for extended-temperature applications; the difference lies in guaranteed accuracy, not range. |
| Output Current Sensitivity | 1 µA/K | 1 µA/K | The 1 µA/K transfer function is identical, so both parts interface to the same signal-conditioning circuitry (e.g., a 1 kΩ resistor gives 1 mV/K) without redesign. |
| Supply Voltage Range | +4 V to +30 V | +4 V to +30 V | Identical compliance range means either part can drop into the same supply rail design; no change to bias circuitry is required for substitution. |
| Package | 2-pin TO-52 (metal can) | 2-pin TO-52 (metal can) | Same hermetic TO-52 footprint ensures pin-for-pin and mechanical compatibility, so the LF can directly replace the JF on an existing PCB. |
| Long-Term Drift | ±0.1°C/month (typical, non-cumulative) | ±0.1°C/month (typical, non-cumulative) | Matching drift specifications mean long-term stability is equivalent, so substitution does not degrade recalibration intervals or lifetime accuracy. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD590LF | AD590JF |
|---|---|---|
| Part Status | Active | Active |
| Sensor Type | Analog, Local | Analog, Local |
| Sensing Temperature - Local | -55°C ~ 150°C | -55°C ~ 150°C |
| Output Type | Analog Current | Analog Current |
| Voltage - Supply | 4V ~ 30V | 4V ~ 30V |
| Accuracy - Highest(Lowest) | ±1°C | ±5°C |
| Test Condition | 25°C | 25°C |
| Operating Temperature | -55°C ~ 125°C | -55°C ~ 125°C |
| Mounting Type | Surface Mount | Surface Mount |
The primary difference is the specified accuracy grade. The AD590JF is a J-grade device with a calibration error of ±5°C maximum at 25°C, while the AD590LF is an L-grade device with a tighter calibration error of ±1°C maximum at 25°C. Both are otherwise functionally identical two-terminal current-output temperature transducers from Analog Devices.
Yes. Both the AD590JF and AD590LF are offered in the same 2-pin TO-52 (TO-206AB) hermetic metal can package with identical pin functions (current output and supply/return). They share the same footprint and can be interchanged on an existing PCB without layout changes.
Both the AD590JF and AD590LF provide a linear current output of 1 µA/K and operate over a supply voltage range of +4 V to +30 V. The output current is proportional to absolute temperature, allowing direct reading in kelvins without linearization circuitry.
Both devices are specified for operation over the full military temperature range of −55°C to +150°C. The J and L accuracy grades differ in calibration error at 25°C, but both are rated for the same extended operating temperature range.
Yes, in most cases. Because the AD590LF has a tighter calibration error (±1°C vs ±5°C at 25°C) and the same package, pinout, output scale factor, and supply range, it can replace the AD590JF where improved initial accuracy is desired. The system's error budget and any calibration trim should still be revalidated against the datasheet limits.
Both grades share the same core die and are specified with the same nonlinearity of ±0.5°C maximum over the rated temperature range and the same long-term drift specification per the Analog Devices datasheet. The grade designation distinguishes calibration accuracy at 25°C, not the underlying linearity or drift performance.
Both the AD590JF and AD590LF require a supply of +4 V to +30 V and present a high output impedance that maintains current accuracy over a compliance voltage range. The output current remains essentially independent of voltage across the specified compliance range, enabling remote sensing over long cable runs.